Off-Board Sensor Loops
The DX2010 can also be mounted to the back wall of the control panel enclosure. See Figure 15.
DX2010
Terminals
Optional mounting locations for DX2010
inside control panel enclosure
8.2.3

DX2010 to Panel SDI Bus Connections

Connect the panel's Data and Aux Power terminals to the DX2010 Module as shown in Figure 16. Refer to Table 8 for the SDI
bus wiring length requirements.
Panel to DX2010
DX2010 AUX Output NOT Used
Panel to DX2010
DX2010 AUX supplying 100 mA
* Wire length may be restricted by panel limitations. See the Installation Guide for more
information.
** If the DX2010 is powered directly by an external auxiliary power supply (Figure 18),
use the wire lengths specified in the first row.
The wire lengths shown in Table 8 must be shared by all devices connected to the terminals.
Do not use twisted pair or shielded cable. Do not share cable with the keypad lines. The maximum distance may be
limited to 76 m (250 ft.) if the Aux Output is used. See Section 8.2.4 DX2010 Auxiliary Output Connections.
IMPORTANT
45349E
D6412/D4412 PCB
JP1
AUXILIARY
Installer
R
R1
JP2-PO1
T1
Select
R
T
Y
G
B
Alrm
-
PO1
+
A
B
L-1
Com
L-2
L-3
Com
L-4
L-5
Com
L-6
L-7
Com
L-8
+
DX2010
Terminals

Figure 15: Optional Enclosure Mounting Locations for the DX2010

Table 8: DX2010 Wire Lengths

D6412/D4412 Operation and Installation Guide
Corner of
DX2010 PCB
Mounting Clip Assembly
22 AWG (0.8 mm)
18 AWG (1.2 mm)
305 m (1000 ft.)*
610 m (2000 ft.)*
30 m (100 ft.)**
Page 34
Mounting
Enclosure
Clip
Standoff
=
76 m (250 ft.)**
© 2003 Bosch Security Systems