DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
PIN, User #
Address: See Table 28
Default:
User 1: 1, 2, 3, 4, 5, 6, 7
-
Users 2-32: 15, 15, 15, 15, 15, 15, 15
-
Selections: 0 to 9
Enter a PIN for each user in the PIN parameter. The PIN length parameter determines the number of
digits in the PINs.
The default PIN length is 4 digits, which makes all User PINs four digits in length. For example, if a
User PIN is 7654321 and the PIN length is set to 4 digits, the User PIN changes to 7654.
Do not use digits 10-15 when creating a User PIN. Entering these digits makes the PIN
unusable and locks the user out of the control panel.
Authority Level, User #
Address: See Table 10
Default:
User 1: 1 (Authority Level 1)
-
Users 2 to 32: 0 (No Authority Level assigned)
-
Selections:
0 = No Authority Level assigned (Disabled)
-
1 = Authority Level 1 assigned
-
2 = Authority Level 2 assigned
-
3 = Authority Level 3 assigned
-
4 = Authority Level 4 assigned
-
This parameter assigns an authority level to each user. The authority level assigns functions to the
user's PIN and RF keyfob. See "RF Keyfobs" in the DS7200V2 Expert Programming Guide (P/N:
4998153891) for a description of RF keyfobs and how to assign them to users.
Authority levels are configured as shown below. See "Authority Level Configuration" in the DS7200V2
Expert Programming Guide (P/N: 4998153891) to change the configuration of authority levels.
Authority Level 1 (Master): All options except for Option 5. A user with this authority level
configuration can arm and disarm the system, send reports, and perform all system functions
except one-time disarm.
Authority Level 2 (Unlimited): All options except for Option 5 and 14. A user with this authority
level configuration can arm and disarm the system, send reports, and perform all system functions
except one-time disarm and change PINs.
Authority Level 3 (User): All options except for Options 5 and 8 to 15. A user with this authority
level configuration can arm and disarm the system, send reports, but can only perform a limited
number of system functions.
Authority Level 4 (One-Time): All options except 7 to 15. A user with this authority level
configuration can arm and disarm the system (can only disarm the system once), send reports, but
can only perform a limited number of system functions and cannot force-arm or bypass zones
when arming the system.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02