DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
Days Option 1, Sked #
•
Address: See Table 38 on page 96
•
Default: 0
•
Selections: 0 to 15
Sked Days 1 Option
No Option Selected
Every Day
Monday
Tuesday
Wednesday
This parameter assigns the day of the week the Sked occurs.
Entering zero (0) for this parameter disables the Sked if no selection is made in the Days
Option 2, Sked # parameter.
If the "Every Day" option is selected in the Days Option 1, Sked # parameter, it overrides
any selection made in the Days Option 2, Sked # parameter.
Days Option 2, Sked #
•
Address: See Table 38 on page 96
•
Default: 0
•
Selections: 0 to 15
Sked Days 2 Option
No Option Selected
Thursday
Friday
Saturday
Sunday
This parameter assigns the day of the week the Sked occurs.
Entering zero (0) for this parameter disables the Sked if no selection is made in the Days
Option 1, Sked # parameter.
If the "Every Day" option is selected in the Days Option 1, Sked # parameter, it overrides
any selection made in the Days Option 2, Sked # parameter.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Enter This Data Digit to Select Options
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
•
•
•
•
•
•
•
•
•
Enter This Data Digit to Select Options
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
•
•
•
•
•
•
•
•
•
•
•
•
•
EN | 98
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•