Bosch DS7200V2-EXP Installation Manual page 114

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 4. Reference Materials
Table 40:
Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
87
Missing,Alarm
88
Missing,Trouble
89
Open,Skd
90
Open,RPS
91
Open,Usr
92
Open,KS
93
Open,Skd,Alarm
94
Open,RPS,Alarm
95
Open,Usr,Alarm
96
Open,KS,Alarm
97
Reserved
98
Params Changed
99
Phone Line Fail
100
Phone Line Rstl
101
Bad Call to RPS
102
RPS Access Fail
103
RPS Access OK
104
Re-Boot,Panel
105
Re-Boot,Dbus
106
Output Reset,Usr
107
Output Reset,Skd
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
SIA Report
Contact ID
Report
UZ Untyped
150 General
Missing Alarm
Alarm
UY Untyped
382 Loss of
Missing Trouble
supervision –
RPM
OA Automatic
403 Automatic
Opening
O/C
OQ Remote
400
Opening
Open/Close
OP Opening
401 O/C by
Report
User
OS Opening
409 Keyswitch
Keyswitch
O/C
OR Disarm from
403 Automatic
Alarm
O/C
OR Disarm from
400
Alarm
Open/Close
OR Disarm from
401 O/C by
Alarm
User
OR Disarm from
409 Keyswitch
Alarm
O/C
YG Parameter
306 Panel
Changed
Programming
Changed
LT Phone Line
351 Telco 1
Trouble
fault
LR Phone Line
351 Telco 1
Restoral
fault
RA Remote
413
Programmer Call
Unsuccessful
Failed
access
RU Remote
413
Unsuccessful
Program Fail
access
RS Valid Remote
412
Access
Successful
Download/Acc
ess
RR Power Up
305 System
reset
RR Power Up
339 Exp.
Module Reset
RO Relay Open
320
Sounder/Relay
RO Relay Open
320
Sounder/Relay
Event Description
Zone assigned to zone expander
(wired or RF) not responding to
panel's status poll while the area
is armed.
Zone assigned to zone expander
(wired or RF) not responding to
panel's status poll while the area
is disarmed.
Opening by Sked.
Opening by RPS.
Opening by user, ID reported.
Opening by Keyswitch.
Opening after Alarm event by
Sked.
Opening after Alarm event by
RPS.
Opening after Alarm event, ID
reported.
Opening after Alarm event by
Keyswitch.
Panel Parameters Changed.
Phone line voltage less than 3
volts for 40 sec.
After Phone Line Fail event,
phone line voltage detected at
greater than 3 volts for 40 sec.
Panel attempted call to RPS, but
was unsuccessful.
RPS attempted to connect to
panel but was not successful.
RPS successfully connected to
and disconnected from panel.
Normal start up or reset after
programming.
Unexpected reset (reboot) from
Data Bus device.
Output Reset by User
Output Reset by Sked
EN | 114
Zone Types
RPS
Linked to
Event
Event
Group
6- 24-hr Burg
3
10-15 Zone
Types
3-8, 10-15 Zone
6
Types
10
10
10
10
10
10
12
12
12
12
12
16
16
Status
Report
R
R
S
R
S
R
R
R
R
S
R
S
R
R