Bosch DS7200V2-EXP Installation Manual page 115

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 4. Reference Materials
Table 40:
Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
108
Output Reset,RPS
109
Output Set,Usr
110
Output Set,Skd
111
Output Set,RPS
112
Rstrl,Tamper
113
Rstrl,Emergency
114
Rstrl,Panic
115
Rstrl,Invisible
116
Rstrl,24-hr Burg
117
Rstrl,Cntrl,Dly
118
Rstrl,Cntrl
119
Rcvr Jam
120
Rcvr Jam Rstl
121
RF Battery Low
122
RF Battery Rstl
123
RF Tamper Trbl
124
RF Tamper Rstl
125
Dbus Missing
126
Dbus Missng,Rstl
127
Dbus Tamper
128
Dbus Tamper,Rstl
129
Dbus Trouble
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
SIA Report
Contact ID
Report
RO Relay Open
320
Sounder/Relay
RC Relay Close
320
Sounder/Relay
RC Relay Close
320
Sounder/Relay
RC Relay Close
320
Sounder/Relay
TR Tamper
137 Tamper
Restoral
QR Emergency
101 Personal
Restoral
Emergency
PR Panic
120 Panic
Restoral
HR Holdup
120 Panic
Restoral
BR Burglary
133 24hr
Restoral
(Safe)
BR Burglary
134 Entry/Exit
Restoral
BR Burglary
130 Burglary
Restoral
XQ RF
344 RF
Receiver Jam
Interference
Detect
XH RF
344 RF
Interference
Receiver Jam
Detect
Restoral
Restoral
XT Transmitter
384 RF Low
Battery Trouble
Battery
XR Transmitter
384 RF Low
Battery Restoral
Battery
TT Tamper
383 Sensor
Trouble
Tamper
TR Tamper
383 Sensor
Trouble Restore
Tamper
EM Expansion
333 Exp.
Module
Device Missing
Failure
EN Expansion
333 Exp.
Missing Restore
Module
Failure
ES Expansion
341 Exp.
Device Tamper
Module
Tamper
EJ Expansion
341 Exp.
Tamper Restore
Module
Tamper
ET Expansion
330 System
Trouble
Peripheral
Trouble
Event Description
Output Reset by RPS
Output Set by User
Output Set by Sked
Output Set by RPS
Restoral from alarm, Tamper
zone type.
Restoral from alarm, Emergency
zone type.
Restoral from alarm, Panic zone
type.
Restoral from alarm, Invisible
zone type.
Restoral from alarm, 24-hour
burglary zone types.
Restoral from alarm, Delay 1 or 2
zone types.
Restoral from alarm, Keyswitch,
Follower, or Instant zone types.
Jammed condition detected on
premises RF receiver.
Jammed condition detected on
premises RF receiver cleared.
Low Battery detected on
premises RF transmitter.
Low Battery condition detected
on premises RF transmitter
cleared.
Premises RF Transmitter Tamper
Fault (Trouble).
Premises RF Transmitter Tamper
Restoral.
Data Bus device not responding
to polling.
Data Bus device declared as
missing now responding to
polling.
Tamper open on Data Bus Device
Tamper.
Data Bus Device Tamper
Restoral.
Fault (Trouble) detected on Data
Bus Device.
EN | 115
Zone Types
RPS
Linked to
Event
Event
Group
16
16
4- Tamper
8
5- Emergency
8
6- Visible Panic
8
7-Invisible
8
Panic
6- Burglary
8
15 – Door
11- E/E Delay 1
8
12- E/E Delay 2
6- Keyswitch
8
13- Follower
14- Instant
9
9
Any zone type
9
Any zone type
9
Any zone type
9
Any zone type
9
12
12
12
12
12
Status
Report
R
R
R
R
R
S
R
S
R
S
R
S
R
S
R
S
R
S

Hide quick links:

Advertisement

Table of Contents
loading