DS7200V2-EXP | Installation Guide | 4. Reference Materials
Table 40:
Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
74*
Duress
75
Fire,Alarm
76
Fire,Cross
77
Fire,Un-verified
78
Fire, Missing
79
Fire,Alrm,Rstl
80
Fire,Trouble
81
Fire,Trbl,Rstl
82
Instl Mode,Start
83
Instl Mode,End
84
Log Overflow
85
Log Threshold
86
AltCom Low Signl
* This event reports a user number + 200 when sent using SIA and Contact reporting formats.
** See the DS7200V2 Expert Programming Guide (P/N: 4998153891) for information on [Q] button programming.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
SIA Report
Contact ID
Report
HA Hold Up
121 Duress
Alarm
FA Fire Alarm
110 Fire
FM Fire Alarm
110 Fire
Cross Zone
FG Unverified
378 Cross-
Event-Fire
zone Trouble
FY Missing Fire
373 Fire
Trouble
Trouble
FH Fire Alarm
110 Fire
Restore
FT Fire Trouble
373 Fire
Trouble
FJ Fire Trouble
373 Fire
Restore
Trouble
LB Local
466 Service
Program
On Premises
LX Local
466 Service
Programming
Off Premises
Ended
JO Log Overflow
624 Event Log
Overflow
JL Log
623 Event Log
Threshold
XL Low Received
350
Signal Strength
Communicatio
n Trouble
Event Description
User entered Duress PIN or
pressed Panic key sequence or
[Q] button** on RF Keyfob. The
Duress report is sent in addition
to any other report that the
user's action would generate.
Alarm event on fire zone type.
Verified alarm event on fire zone
type with Cross Zone Option.
See "Zone Response Options" in
the DS7200V2 Expert
Programming Guide (P/N:
4998153891).
Unverified alarm event on fire
zone type with Cross Zone
Option. Or unverified event on
Fire Verify zone type.
Fire zone type assigned to zone
expander (wired or RF) not
responding to panel's status poll.
Restoral from alarm, Fire zone
types.
Fault (Trouble) condition on Fire
zone types.
Restoral from Trouble, Fire zone
types.
Installer PIN entered. Installer
mode accessed.
Installer mode exited.
Panel log overflow condition.
Oldest events being overwritten.
Panel log reached threshold. See
"Log Supervision Configuration"
in the DS7200V2 Expert
Programming Guide.
Low Signal Strength detected on
Alternate Communication device.
EN | 113
Zone Types
RPS
Linked to
Event
Event
Group
1
1- Fire
2
2- Fire with
Alarm
Verification
1- Fire
2
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
7
2- Fire with
Alarm
Verification
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
7
2- Fire with
Alarm
Verification
11
11
12
12
12
Status
Report
R
R
R
R
R
S