DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
Table 34:
Output Function Types (continued)
Digit
Digit
1
2
0
11
Exit Delay, Entry Delay, Chime
0
12
Phone Line Fail
0
13
Ack Received (any report)
0
14
AC Fail
0
15
Low or Missing Battery
1
0
PO 2 (on-board) Siren
Supervision Fail
1
1
Sensor Trouble Monitor
1
2
Duress, [#][4][7] (reset)
resets
1
3
User Tamper, [#][4][7] (reset)
resets
1
4
Arming Beeps (for
keyswitch/RF arming)
1
5
Bell Time – Starts on any
Alarm Event. PIN entry Stops.
Activates on Bell Test.
1
6
Strobe
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Function Type
Output activates at the start of Exit Delay or Entry Delay. For Steady or
Pulse modes, the output remains activated until Entry or Exit Delay ends.
The output also activates whenever a Chime zone is faulted. The output
does not activate on Chime if Chime Tone is turned off.
Output activates when a Phone Line Fail condition is detected. For
Steady or Pulse modes, the output remains activated until the condition
is cleared. This output works independently of
Response Options
Output activates when the acknowledgement for any report is received.
For Steady or Pulse modes, [System Reset] resets. This output type is
event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page 93
for more information.
Output activates when a AC Fail condition is detected. For Steady or
Pulse modes, the output remains activated until the condition is cleared.
Output activates when a control panel Low or Missing Battery condition
occurs. For Steady or Pulse modes, the output remains activated until
the condition is cleared.
Output activates when a Siren Supervision Fail condition is detected. For
Steady or Pulse modes, the output remains activated until the condition
is cleared and [System Reset] is pressed.
Output activates when a Sensor Trouble Monitor condition is detected in
conjunction with the selection made for the Sensor Monitor Time
setting. For Steady or Pulse modes, the output remains activated until
the Sensor Monitor Trouble condition is cleared.
Output activates whenever a Duress PIN is entered. For Steady or Pulse
modes, the output remains activated until user presses [System Reset].
Output activates on a User Tamper event. For Steady or Pulse modes,
the output remains activated until user presses [System Reset].
Disarm/All On/Perimeter Only/Partial On Beeps for keyswitch/RF arming.
1=Off, 2=All, 3=Perimeter Only. Mode and Time parameters do not apply.
This function works in conjunction with Address 1039 (See "Global
Output Options" in the
4998153891)). Available for on-board outputs only.
Output activates on any alarm event. Entering PIN terminates Bell Time.
For Steady and Pulse modes, the output remains activated for the
duration programmed in the Bell Time parameter.
Activates on Bell Time or output function as programmed. See "Strobe
Output Type Options" in the DS7200V2 Expert Programming Guide
(P/N: 4998153891). PIN entry resets the function.
Description
(page 57).
DS7200V2 Expert Programming Guide
EN | 89
Phone Line Fault
(P/N: