Figure 59: Dacm To Control Panel Wiring; Figure 60: Dacm To Control Panel Wiring (External Power Supply) - Bosch DS7200V2-EXP Installation Manual

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
You can use either one of the Aux Power (-)
terminals and either one of the 12 VDC (+)
terminals when connecting devices to the control
panel.
Figure 59:
DACM to Control Panel Wiring
1
1- DACM
2- Control Panel
3- Wire Harness (supplied with DACM)
4- Green (G) wire
5- Yellow (Y) wire
6- Black (-) wire
7- Red (+) wire
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
2
3
4
5
6
7
BATT+
BATT-
You can use either one of the Aux Power (-)
terminals when connecting to the control panel.
Do not tie the black (-) output to
earth ground when using any external
power supply. A ground fault
condition is reported if black (-) is
grounded.
Figure 60:
DACM to Control Panel Wiring
(External Power Supply)
1
7
(+)
(-)
8
1- DACM
2- Control Panel
3- Wire Harness (supplied with DACM)
4- Green (G) wire
5- Yellow (Y) wire
6- Black (-) wire
7- Red (+) wire
8- External 12 VDC power supply
2.10.3 DACM Supervision
The control panel supervises communication to
the DACM. If it fails to communicate with the
DACM, it sends a "DBus Missing" {125} report.
EN | 39
2
3
4
5
6
BATT+
BATT-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents