Start iSCSI DHCP Refresh

Syntax
start controller [(0 | 1)] iscsiHostPort [(1 | 2 | 3 | 4)] dhcpRefresh
Parameters
Parameter
controller
iscsi-host-port
NOTE: This operation ends the iSCSI connections for the portal and brings down the portal
temporarily.

Start Physical Disk Blink

Description
This command blinks a physical disk by turning on an indicator light on the physical disk. Run the stop
physicalDisk blink command to turn off the indicator light on the physical disk.
Syntax
start physicalDisk [enclosureID,slotID] blink
Parameters
Parameter
physicalDisk
Description
The identifier letter of the RAID controller module
that has the iSCSI host ports. Valid RAID controller
module identifier values are 0 or 1, where, 0 is the
RAID controller module in slot 0, and 1 is the RAID
controller module in slot 1.
The identifier of the port on the storage array on
which you want to refresh the DHCP parameters.
Enclose the iSCSI host port name in square
brackets ([ ]).
Description
The location of the physical disk that you want to
find. For high-capacity expansion enclosures,
specify the enclosure ID value and the slot ID value
of the physical disk that you want to revive.
Enclosure ID values are 0 to 99. Slot ID values are
0 to 31. Enclose the enclosure ID value and the slot
ID value in square brackets ([ ]).