Electrical Specifications

AC Operating Power Limits and Ranges

The information in this section applies to the AC version of the Netra 440 server.
TABLE C-2
440 server, and
server as a whole.
TABLE C-2
Description
Operating input voltage range
Operating frequency range
Maximum operating input current
Maximum operating input power
TABLE C-3
Description
Operating input voltage range
Operating frequency range
Maximum operating input current
Maximum operating input power
Note – The figures for the maximum operating current are provided to help you
specify the fusing and cabling you need to deliver power to your equipment.
However, these figures represent worst-case scenarios.
134
Netra 440 Server Service Manual • August 2004
gives AC power source requirements for each power supply in the Netra
gives AC power source requirements for the Netra 440
TABLE C-3
AC Operating Power Limits and Ranges for Each Power Supply in the Netra
440 Server
AC Operating Power Limits and Ranges for the Netra 440 Server
Limit or Range
90 - 264 VAC
47 - 63 Hz
5.5 A @ 90 VAC
500 W
Limit or Range
90 - 264 VAC
47 - 63 Hz
11 A @ 90 VAC
1000 W