Power ON or OFF

Enable (
) Power On to enter STANDBY mode. Power to projector components is present. Disable
checkbox to turn power OFF.

Turn Lamp ON or OFF

Enable Lamp On (
ON, the button is grayed out. Disable checkbox to turn the lamp OFF.

Open or Close Douser (Shutter)

Enable Douser Open (

Display Test Pattern

Enable Test Pattern On (
Pattern menu. If more than 1 test pattern is programmed, selecting it again obtains the next test pattern
in the sequence. To return to the program, select a Channel button again.

Move Auxiliary Lens

Toggle the current location of the optional motorized auxiliary lens mount; position it either in front of
the primary lens (enable Auxiliary Lens (
checkbox).

Intelligent Lens System (ILS)

Select ILS to bring up the control screen used to adjust focus, XY offset and zoom of the ILS. This
menu also enables users to manually override the intelligent lens system settings. When the channels
are changed, the ILS automatically moves the lens to adjust the focus, horizontal (X) and vertical (Y)
offset, and zoom based on the pre-defined settings. Allmanual override settings are lost. This feature
should only be used to make quick changes. Proper adjustments should be made in the Channel:Lens
menu when time permits. There are a total of 64 channels available. When ILS is enabled and the
channel has been specified it begins adjusting each motor. The proper lens type must be selected from
the Advanced:Lens menu beforehand. The position of each motor is then saved onto the system in the
specific channel file. This is not a global feature - instead it is controlled on a per channel basis. When
this feature is enabled the ILS for the currently selected channel is turned ON. NOTES: 1) Operator
access rights required to access ILS from the Main menu. 2) Only Advanced users can modify channel
settings.
CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)
) to turn the lamp ON. If an error exists, which will not allow the lamp to turn
) to open the douser. Disable checkbox to close the douser.
) to display the set of test patterns pre-selected from the Advanced: Test
) checkbox), or move it out (disable Auxiliary Lens
Section 2: Basic Operation