13. Close the rear access door. NOTE: Ensure the hex key is placed back into its holder before closing
the rear access door.
14. Record the serial number of the new lamp.
a. Plug in the projector and power it up.
b. In the Lamp menu, select Change Lamp.
c. In the Lamp S/N text box, enter the serial number.
d. Press Enter to record the number and to reset the lamp timer. The timer begins to log time for
the new lamp.
15. Ensure LampLOC™ is adjusted.
4.2

FILTER REPLACEMENT

Use only special, high efficiency Christie approved filters. Never operate the projector
without the filter installed. The air filters in this product cannot be cleaned properly;
therefore, never reuse an old air filter. Failure to comply can lead to contamination of
the optical components.
Replace the air filter (003-002311-xx) whenever the lamp module is replaced or sooner if operating the
projector in a dusty or dirty environment. Check monthly in all cases. The filter is located on the front
of the projector, behind the air filter cover (Figure 4-2).
1. Remove the 2 captive screws at the bottom of the
filter door (Figure 4-2). Lift the door up and away
from the projector.
2. Slide the air filter out and discard. Insert the new
air filter with the arrow indicator (marked on the
side) pointing towards the airflow.
3. Replace the filter door and tighten the 2 captive
screws.