3 Installation & Setup
All installation procedures must be performed by a qualified technician
in a restricted access location.
When transporting the projector from a cold environment it is essential
that the projector acclimatize for a minimum of 3 hours before powering
up. Failure to comply could damage projector electronics. This also
applies to the lamp, which will be damaged if it is powered ON when
below room temperature. Store lamp between 25-65°C (77-149°F).
Ensure the following tools and components are on hand before beginning. NOTE: In general, fasteners
are metric sizes and require metric tools. However, to complete lamp installation imperial tools are
required, which are provided inside the lamp door of the projector.
 12" screwdrivers: Phillips® #2 (magnetic) and flat
 19mm and 7/8" wrenches
 Assorted Allen® keys (metric)
 Single-phase 20A connection of AC supply to accommodate N6-20P plug
 Protective clothing/safety gear (required when handling the lamp)
 Lens cleaning tissue and solution
CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)
WARNING
WARNING
3-1