Msm Leds - Extreme Networks BlackDiamond 8800 Series Hardware Installation Manual

Consolidated extremexos
Hide thumbs Also See for BlackDiamond 8800 Series:
Table of Contents

Advertisement

MSM LEDs

Table 15
describes the LED activity on the BlackDiamond 10808 MSM.
Table 15: MSM LEDs
LED
Color
SYS
Green blinking
Amber blinking
Amber
Off
MSTR
Green
Amber
ENV
Green
Amber
ERR
Amber
Off
Link/Activity
Off
Green
Amber
NOTE
To reset the critical software error LED (amber ERR LED), use the clear log static command and reboot the
switch. If you continue to have critical software errors, or the ERR LED is amber after the clear log static
command and a switch reboot, contact Extreme Networks Customer Support.
Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide
Indicates
Normal operation is occurring.
Diagnostic test is in progress.
Diagnostic failure has occurred.
Switch is not receiving power.
Module is operating as primary.
Module is operating as backup.
Environment (temperature, fan, power supply) is operating properly.
Environmental failure has occurred.
A critical software error has been logged since power up.
Normal operation is occurring.
Link is down.
Link is up.
Packet activity is occurring.