Installing Summit Family Switches
Table 36
lists the technical specifications for the internal DC power supply.
Table 36: Summit X450a family internal DC power supply specifications
Characteristic
Summit X450a-24tDC
Nominal input voltage
Summit X450a-24xDC
Nominal input voltage
Summit X450a-48tDC
Nominal input voltage
Operational voltage
range
Summit X450a-24tDC
Input current
Summit X450a-24xDC
Input current
Summit X450a-48tDC
Input current
Inrush current
Input wire harness
Wire size
Connector on cable
Ambient operating
conditions
Storage and
transportations

Attaching the DC Wiring Harness to the DC Power Socket on the Switch

After the DC wiring harness is connected to a permanent DC voltage source by a qualified, licensed
electrician, you can remove, replace, and maintain the Summit X450a-24tDC, Summit X450a-24xDC, or
Summit X450a-48tDC system without further electrician assistance.
NOTE
Be sure that the DC circuit is de-energized before you connect the DC wiring harness to the DC power socket.
CAUTION
Be sure that proper ESD controls are in use before switch maintenance is performed. This includes but is not
limited to wrist straps that are grounded to the switch chassis and earth grounds.
To attach the DC wiring harness to the internal DC power supply, perform the following steps:
1 Plug the DC wiring harness connector into the DC power supply socket on the rear of the switch
(see
Figure
The pins must align properly for the cable to completely connect. Do not force the cable into the
socket until the keyway is aligned properly. Refer to
290
Specification
-48 V
, 2.0 A
-48 V
, 2.5 A
-48 V
, 4.5 A
-36 to -72 V
2.0 A at -36 V
2.5 A at -36 V
6.0 A at -36 V
40 A peak maximum
Extreme PN 250088
14 AWG
TYCO PN 206060-1
0°C to 40°C
-40°C to 70°C
202).
, 1.0 A at -72 V
, 1.25 A at -72 V
, 2.0 A at -72 V
Figure 201
for the DC wiring harness connector.