Safety Information
NOTE
Tray Cable is a UL US only requirement. Outside United States standard 8 AWG (8.35mm
acceptable.
Wall plug: N/A, 3-conductor wires have been stripped and are ready for connection to DC power
source mains
Device Connector: Molex Shell Connector PN 42816-0312; Molex Pin Connectors PN 42815-0032
Assembly Rating: 75VDC, 30A, (Do not disconnect under load)
WARNING!
When using multiple power supplies, make sure that each power supply is attached to independent circuits breakers.
See PS installation instructions of PS for proper sizing of circuit breaker.
Make sure that the source outlet is properly grounded according to the country's local electrical requirements before
plugging the AC supply power cord into a PSU.
For specific product input power requirements refer to the data sheet of the product or modular PSU at http://
www.extremenetworks.com or to Appendix B of this guide.
The following countries have specific safety instructions concerning power connectors:
Argentina: The supply plug must comply with Argentinean standards.
Australia: Use AS 3112 for 110/220 VAC power supplies.
Denmark: The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
International: Use CEE 7/7 for 110/220 VAC power supplies.
Japan:
Use JIS 8303 for 110/220 VAC power supplies.
The power cord provided with the power supply, switch, or chassis is for use only with that
specific product from Extreme Networks; it is not for use with any other product from Extreme
Networks or any other vendors' equipment.
North America: The cord set must be cULus listed or cCSAus listed.
Switzerland: The supply plug must comply with SEV/ASE 1011.
United Kingdom: Use BS 1363 for 110/220 VAC power supplies.
NOTE
This equipment is not intended to be directly powered by power distribution systems where phase-phase voltages
exceed 240V AC (2P+PE), such as those used in Norway, France, and other countries. For these applications it is
recommended that a transformer be used to step down the voltage to < 240V AC from phase-phase, or that you
make a connection to a (P+N+PE) power distribution where voltages do not exceed 240V AC.
All installations should confirm that the product is reliably grounded according to the country's local electrical
codes.
NOTE
Building codes vary worldwide; therefore, Extreme Networks strongly recommends that you consult an electrical
contractor to ensure proper equipment grounding and power distribution for your specific installation & country.