Lbu Register Description - Siemens Ertec 400 Manual

Enhanced real-time ethernet controller
Table of Contents

Advertisement

7.5

LBU Register Description

LBU_P0_RG_L
LBU_P1_RG_L
LBU_P2_RG_L
LBU_P3_RG_L
Description
Low word of LBU Pagex_Range_register
Bit No.
Name
15..0
LBU_P0_RG_H
LBU_P1_RG_H
LBU_P2_RG_H
LBU_P3_RG_H
Description
High word of LBU Pagex_Range_register
Bit No.
Name
15..0
LBU_P0_OF_L
LBU_P1_OF_L
LBU_P2_OF_L
LBU_P3_OF_L
Description
Low word of LBU Pagex_Offset_register
Bit No.
Name
15..0
LBU_P0_OF_H
LBU_P1_OF_H
LBU_P2_OF_H
LBU_P3_OF_H
Description
High word of LBU Pagex_Offset_register
Bit No.
Name
15..0
LBU_P0_CFG
LBU_P1_CFG
LBU_P2_CFG
LBU_P3_CFG
Description
Configuration for the individual pages
Bit No.
Name
15..1
0
PAGE_X_32
Copyright © Siemens AG 2010. All rights reserved.
Technical data subject to change
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
Description
Lower 16 bits for area setting
15:8 are read/write accessible
7:0 are read-only (value: 00h)
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
Description
Upper 16 bits for area setting
15:6 are read-only (value: 000h)
5:0 are read/write accessible
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
Description
Lower 16 bits for offset setting
15:8 are read/write accessible
7:0 are read-only (value: 00h)
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
Description
Upper 16 bits for offset setting
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
W/R
Addr.:
LBU_CS_R_N
Description
Reserved
1: Page is a 32-bit page
0: Page is a 16-bit page
Page
+0x00
Default: 0x0000_0000
+0x10
Default: 0x0000_0000
+0x20
Default: 0x0000_0000
+0x30
Default: 0x0000_0000
+0x02
Default: 0x0000_0000
+0x12
Default: 0x0000_0000
+0x22
Default: 0x0000_0000
+0x32
Default: 0x0000_0000
+0x04
Default: 0x0000_0000
+0x14
Default: 0x0000_0000
+0x24
Default: 0x0000_0000
+0x34
Default: 0x0000_0000
+0x06
Default: 0x0000_0000
+0x16
Default: 0x0000_0000
+0x26
Default: 0x0000_0000
+0x36
Default: 0x0000_0000
+0x08
Default: 0x0000_0000
+0x18
Default: 0x0000_0000
+0x28
Default: 0x0000_0000
+0x38
Default: 0x0000_0000
82
ERTEC 400 Manual
Version 1.2.2

Advertisement