Intel server system
Table of Contents

Advertisement

2. Open the server chassis.
3. Move the jumper from the normal operation position, Password Clear Protect, at
pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3 as
indicated in the following diagram.
4. Reconnect the AC power, power up the system.
5. Power down the system and disconnect the AC power.
6. Return the Password Clear jumper to the Password Clear Protect position, covering
pins 1 and 2.
7. Reconnect the AC power and power up the server.
8. Close the server chassis. The password is cleared and can be reset by going into the
BIOS setup.

Clearing the CMOS

If you cannot access the BIOS setup screens, you must use the CMOS Clear jumper to
reset the configuration RAM.
1. Power down the system and disconnect the AC power.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the
reset / clear position (covering pins 2 and 3).
24
Password
Default
Clear
2
Password
J1F2
Clear
3

Figure 8. Password Recovery Jumper

AF003181
®
Intel
Server System SR1695GPRX Service Guide