9. System Wiring for Typical Application

DOOR
RELAY
DOOR
LOCK
9-1. Power Connection
- Connect (+) wire of DC 12V power to Red wire
- Connect Power GND (-) wire of DC 12V to Black wire
9-2. Door Lock Connection
9-2-1 Connection of POWER FAIL SAFE: Door Lock
- Connect Door RELAY(COM), Grey/Red stripe wire to DC +12V ( be sure that the existing
power supply has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Door Lock to Door RELAY (NC), Blue/White stripe wire of main unit.
- Connect (-) wire of Door Lock to Power GND (-) wire of main unit.
9-2-2 Connection of POWER FAIL SECURE: Door Lock
- Connect Door RELAY(COM), Grey/Red stripe wire to DC +12V ( be sure that the existing
power supply has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Door Lock to Door RELAY(NO), White/Red stripe wire of main unit.
- Connect (-) wire of Door Lock to Power GND(-) wire of main unit.
505R-20011128
DOOR
RELAY
COM
ALARM
RELAY
NC
NO
EXIT
CONTACT
AUX IN#1
+12V
ALARM
RELAY
COM
+12V
DC 12V
Power
Supply
SIREN
9
ID TECK
ACCESS CONTROLLER
EXIT
BUTTON
DOOR
CONTACT
PIR
SENSOR
GND

Hide quick links: