STAR 505R
When registering cards,
1. The 'PW' is for password input. the password is needed to access doors when the controller
is operating in RF + PW mode. But regardless of the operating mode, it is necessary to input
a password when registering.
2. The 'TS' is for Time Schedule index(01~10). To control the accessible periods of time for
each card, set Time schedules first(see 14.2.1, page 29) and enter the Time Schedule index
number here.
If there is no need to apply the Time Schedule(anytime accessible with that card), enter '00'
for the value.
3. The 'RD' is for selecting accessible reader for the card. Usually '3' (both readers) is used
when using both entry and exit readers. If '1' is entered for the value, only reader 1 will
recognize the card and reader 2 will deny access, indicating 'ACCESS DOOR ERR' on the
LCD (this is also the choice when using a one reader setup, meaning using one reader for
entry and no reader for exit). Likewise, when '2' is entered, only the reader 2 is accessible
with that card and reader 1 access will be denied. And again, both readers are accessible
when '3' is entered for the 'RD' value.