8.2 System Initialization (External Reader Port)

After the installation and connections are completed, apply power (DC12V) to LX505 with the
initialization button being held down. Then, the LCD will first display "Initialize OK? 0:No
1:Yes". Press <1> key if you want to initialize the system. After all the initialization process is
completed, the system will be operating on the normal mode and the LCD will display
"IDTECK, LX505 [F1], Date Time".

8.3 Wall Mount Installation

Position the Wall Mount to the location at which you want to install the unit and mark 4 x
1.
drilling positions. Drill 6-32 holes for at least 4 mounting points.
Drill a 1/2" hole on the center of the Wall Mount.
2.
Using 4 screws, install the Wall Mount to the proper location.
3.
Take out the cable through the center hole.
4.
After the wiring is done as explained in the next section, put the Main Unit on the Wall
5.
Mount and screw it.

8.4 Wiring

8.4.1 Power Connection

Connect (+) wire of DC 12V Power Supply to Red wire.
1.
Connect GND (-) wire of DC 12V Power Supply to Black wire.
2.

8.4.2 Input Connection

Exit Button Connection
Connect one wire from Exit Button to Orange wire.
1.
Connect the other wire from Exit Button to the GND.
2.
Power ON
Initialize OK?
1: Yes 0: No
<1> KEY?
Yes
"SYSTEM
INITIALIZED!!!"
17
Press and hold the
initialization button. Put the
+12V DC power to the LX007.
Release the button when the
LCD displays "Initialize OK?"
No
Normal Operation