STAR 505R
9-3. Alarm Device Connection
- Connect Alarm RELAY(COM), White wire to DC +12V (be sure that the existing power supply
has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Alarm Device to Alarm RELAY(NO), Purple wire of main unit.
- Connect (-) wire of Alarm Device to Power GND(-) wire of main unit.
9-4. Exit Button Connection
- Connect one of the wires of Exit Button to Exit Button Input, Orange wire.
- Connect the other wire of Exit Button to Power GND (-) wire.
9-5. Door Contact Sensor Connection
- Connect Door Contact sensor (COM) wire to Door Contact Input, Yellow/Red stripe wire.
- Connect Door Contact sensor (NO) wire to Power GND (-) wire.
9-6. Auxiliary Input Device connection (Applied to AUX Input #1, #2)
- Connect one wire of the Auxiliary Input Device to the AUX Input wire.
(AUX Input #1: Green wire, AUX Input #2: Green/White stripe wire).
- Connect the other wire of Auxiliary Input Device to Power GND (-) wire.
9-7. Wiegand Input Connection From Another Compatible Wiegand Reader
- Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has enough
capacity to support this accessory or upgrade to a sufficient one.)
- Connect (-) wire of Reader to Power GND (-) wire.
- Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
- Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
9-8. RS-232 Communication Port Connection
9-pin connector (COM Port, female) is required to connect serial communication RS-232
between Main Unit and Personal Computer.
- Connect RS-232-TX, Black with white stripe of Main Unit to pin number 2 of 9-pin connector.
- Connect RS-232-RX, Red with white stripe of Main Unit to pin number 3 of 9-pin connector.
- Connect GND, black wire of Main Unit to pin number 5 of 9-pin connector.
- Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.
- Install and run Application Software.
9-9. RS-422 Communication Port Connection
RS-422/RS-232 converter is required to connect serial communication RS-422 between Main
Unit and Personal Computer.
- Connect RS-422-TX(-), Yellow wire of Main Unit to RX(-) port of converter.
- Connect RS-422-TX(+), Gray wire of Main Unit to RX(+) port of converter.
- Connect RS-422-RX(-), Blue wire of Main Unit to TX(-) port of converter.
- Connect RS-422-RX(+), Brown wire of Main Unit to TX(+) port of converter.
- Plug in RS-232 9-pin connector of RS-422/RS-232 converter to COM1 or COM2 Port of Personal
Computer.
- Install and run Application Software.
505R-20011128