STAR 505R
11-5. Anti-Pass-Back
Using an additional RF reader for exiting, the Anti-Pass-Back mode can be utilized. Anti-pass-back
prevents a registered user from exiting if the user did not properly register when entering. Likewise if the
user has exited without verification by the unit, the user will not be allowed entry on their next attempt.
11-6. Data Backup
The controller retains all user information and event data for over a week, even if the event of loss of
power. Using a battery back up the unit can operate normally for a significant time period, depending on
the power of the battery used.
11-7. Inputs/ Outputs
The STAR505R access controller has four input ports and four output ports(two relay output ports and
two TTL output ports) which can be used to manipulate a wide variety of controls.
11-8. Tamper Alarm
While in operation, if someone attempts to damage or pry the STAR505R from its cabinet, an alarm
will buzzer sound and alarm messages can be sent in a variety of ways. The alarm may be canceled by
presenting a registered card, the master card, or through the host computer.
11-9. Time Schedule
You can program periods of time when each person (ID number) can access the door. Each user can
be programmed individually to address work shifts, weekends and holidays. All scheduling can be
programmed through the keypad and LCD or via the software program on the host computer. Also you
can set periods of time about output following input, and only output, the former correspond to Input, the
latter correspond to Output. So, you can set Input and Output according to each T/S. All these can be
defined through the setup menu or application program.
11-10. Output Behavior Setup
The two relays outputs, two TTL outputs, buzzer sound, etc. are customizable. They may be activated
or deactivated, and in active mode may be programmed for different lengths of time, different responses
to inputs, and can be set through the setup menu or the application program.
11-11. Door Open by Compulsion and Door Open Alarm
When door is opened by compulsion, Door Contact output is generated. And, when the door is being
opened by normal operation, after 20 sec. door-open alarm(blink buzzer and green LED) will be
generated until the door is closed.
11-12. Duress Mode
In case of Duress, enter the 2 digit Duress Password and press <ENT> and open the door using
general process. If you registered ID, then duress output will be generated.
11-13. Programmable ID/EVENT memory
This user friendly device allows you to register 500 ~ 10,000 ID numbers and it can keep 2,500 ~
7,250 events. Number of ID & Event can be exchanged under the ratio of 2 to 1 which means every 500
users can be convert to 250 events.