8.1.4 Single-phase 100 V Series

*1 Fuji's 4-pole standard
*2 The rated capacity is for 220V output voltage.
*3 The inverter cannot output voltage that is 2 or more times its rated voltage.
*4 Tested under the standard load condition (85% load for applicable motor rating).
*5 Calculated under Fuji-specified conditions.
*6 Indicates the value when using a DC reactor (option).
*7 Average braking torque obtained with the AVR control off (F 05 =0). (Varies according to the efficiency
of the motor.)
*8 Average braking torque obtained by use of an external braking resistor (standard type available as
option).
*9 To make FRENIC-Mini compliant with category TYPE1 of the UL Standard (or NEMA1), an optional
NEMA1 kit is required. Note that the TYPE1-compliant FRENIC-Mini should be used in the ambient
temperature range from -10 to +40°C.
Note 1: A box ( ) in the above table replaces A, C, E, or J depending on the shipping destination.
2: When driven by 100 VAC, the single-phase 100 V series of inverters limit their shaft output and
maximum output torque as listed below. This is to prevent their output voltage from decreasing
when load is applied.