Page 38
ImpEp: 0.00KWh Total : 0.00KWh ExpEp: 0.00KWh Total : 0.00KWh 8.2 Submenus in the Main Menu Device Info. << GL3000 SN-13 Fault Record ID:2107279701 ID:2107279701 Inv1400 Inv1400 LcdA238 Device Info. 1 F35 220513 07 Fault Record << 2 F35 220513 06 3 F35 220513 06 4 F35 220513 06...
Page 39
ON / OFF << Turn ON << Setup Turn OFF Turn ON Turn OFF << Cancel << Cancel Setup Branch 1 : 0.0A PV VA << Branch 2 : 0.0A Setup << System Param << PV VA Param Protect Param Comm.
Page 40
Time Set << Display Set Language Set Factory Reset << Factory Reset Set Restore << 20200522 OK English << Polski 08:11:21 Cancel Bright Keep << Polski P CCK << Delay time 05S Delay time 05S Confirm Reset << OK << Cancel Cancel I Confirm <<...
Page 41
PassWord Vref 0.0V ActiveP ReactP 0.0% << Q-Mode OFF << Fun RCD OFF << -1.000 Fun ISO OFF << SelfCheck Island OFF << Limiter Feed-in 0% << Meter MPPT Num WindTurbine <<...
Page 45
Over-frequency Response OFDMode HYS <- OF-Derate ON <- OF-Derate OFF <- Tab. 11-4 Definition of Over- frequency Response Parameters Parameter Range Description Fstr 45HZ-65HZ The Start frequency value for over-frequency response. Fstop 45HZ-65HZ The Stop frequency value for over-frequency response. In hysteresis mode, power is restored only when RecPT 45HZ-65HZ...
Page 46
Fstop Fstop Fstr Fstop Frec 50.10Hz RecDly 0.00 OK << Cancel RecGra 0.00% << The inverter provides a reactive power regulation function. Tap Reactive Power Regulation Mode to select proper regulation mode and set the corresponding parameters. ActiveP ActiveP Q-Mode Q(P) << Q-Mode OFF <<...
Page 47
"Q(U)" Mode "Q(P)" Mode The reactive power output by the inverter is controlled by the active power of the inverter. "PF(P)" Mode The PF is controlled by the active power of the inverter. “PU” Mode WGraStr 0.0% WGraStr 0.0% OFF <- ON <- 0.0% <<...
Page 48
U/Vref (U1,P1) (U2,P2) (U3,P3) (U4,P4) P/Pn parameter Range descrption Value of P/Pn at point (P1,U1) on the PU mode 0%-110% Pn curve Grid voltage limit at point (P1,U1) on the PU mode 0% -150% Vref curve Value of P/Pn at point (P2,U2) on the PU mode 0%-110% Pn curve Grid voltage limit at point (P2,U2) on the PU mode...
Page 50
(U1,Q1) Upper Q/Pn lnd (U2,Q2) (U4,Q4) Grid Voltage (U3,Q3) (U5,Q5) Lower Q/Pn Cap (U6,Q6)
Page 51
Parameter Range Description The QU mode starts when the active power Pstart 0%-130% Rate out power is greater than this value The QU mode stops when the active power Pstop 0%-130% Rate out power is less than this value Value of Q/Pn at point (U1,Q1) on the Q(U) -60% -60% Q/Pn mode curve Grid voltage limit at point (U1,Q1) on the...
Page 52
“Q(P)” Mode Upper Q/Pn lnd (P1,Q1) The reactive power output by the inverter is controlled by the active power of the inverter. P2(P2,Q2) P/Pn P4(P4,Q4) P3(P3,Q3) P5(P5,Q5) Lower P6(P6,Q6) Q/Pn Cap ActiveP 20.0% 0.0% << QMode QP <- 0.0% 0.0% << 0.0% <<...
Page 53
Parameter Description Range Power value/Pn at point (P1,Q1) on the Q(P) mode 0%-100% Pn curve Reactive power value at point (P1,Q1) on the Q(P) -60% -60% Q/Pn mode curve Power value/Pn at point (P2,Q2) on the Q(P) mode 0%-100% Pn curve Reactive power value at point (P2,Q2) on the Q(P) -60% -60% Q/Pn...
Page 54
"PF(P)" Mode The output power factor is controlled by the active power of the inverter. Vstart 0.0% 0.0% Vstop 0.0% -1.000 << 0.0% 0.0% -1.000 << -1.000 << 0.0% 0.0% -1.000 << -1.000 << 0.0% RmpTime -1.000 << Cancel << PF lagging P1(P1,PF1) P2(P2,PF2)
Page 55
Parameter Range Description The PFP mode is enable when grid Vstart 0-150% Vref voltage is greater than Vstart The PFP mode is disable when grid voltage Vstop 0-150% Vref is less than Vstop Power value at point (PF1,P1) on the PF(P) 0-110% Pn Curve PF value at point (PF1,P1) on the PF(P)