P02, P03
Motor Parameters (Rated capacity and Rated current)
Sets the nominal rated capacity that is denoted on the rating nameplate of the
motor.
P09
Motor Parameter (Slip compensation gain)
Sets the gain to compensate for the motor slip frequency. It is based on the typical
slip of every inverter model as 100%. It sets the compensation gain watching the
motor speed.
Typical rated slip frequencies for 100%
Rated capacity
(kW/HP)
0.06/0.1
0.1/0.12
0.2/0.25
0.4/0.5
0.75/1
1.5/2
2.2/3
3.7/5
The above values apply to both the 200 V and 400 V series of inverters.
For the FRN4.0C1 -4 **, the default setting for P02 is 3.7.
Fuji standard
8-series (Hz)
1.77
1.77
2.33
2.40
2.33
2.00
1.80
1.93
For this function which is related with the motor characteristics, the volt-
age at the base frequency (F05) and motor parameters (P codes) should
be also set consistently.
5-38
Typical motors
Fuji standard
rated in HP
6-series (Hz)
(Hz)
2.50
1.77
2.50
1.77
2.50
2.33
2.50
2.40
2.50
2.33
2.50
2.00
1.17
1.80
1.50
1.93
Other motors
(Hz)
1.77
1.77
2.33
2.40
2.33
2.00
1.80
1.93