FujiFilm MEH531 Brochure

Frenic multi series high performance compact inverters

Advertisement

High Performance Compact Inverters
MEH531

Advertisement

Table of Contents
loading

Summary of Contents for FujiFilm MEH531

  • Page 1 High Performance Compact Inverters MEH531...
  • Page 2 With advanced technology built in, these new Gentler on the environment Complies with European regulations that limit the use of specific hazardous substances (RoHS). These inverters are gentle on the environment. Use of 6 hazardous substances is limited.(except for interior soldering in the power module.) <Six Hazardous Substances>...
  • Page 3 inverters can be used for multiple purposes The highest standards of control and performance in its class Shortened setting time in slip compensation control Compatible with PG feedback control Through "slip compensation control" + "voltage tuning," speed ■ Without speed feedback <Example of conveyor operation pattern>...
  • Page 4 Simple and thorough maintenance The life information on each of the inverter's limited life components is displayed. Cooling fan cumulative running time Main circuit capacitor capacity Cumulative running time of the electrolytic Inverter cumulative running time capacitor on the printed circuit board. Simple cooling fan replacement! Information that contributes to equipment maintenance is displayed! Construction is simple, enabling quick removal of the top...
  • Page 5 Consideration of peripheral equipment, and a full range of protective functions! Resistors for suppressing inrush current are built in, making it Side-by-side mounting saves space! possible to reduce the capacity of peripheral equipment. If your control panel is designed to use multiple inverters, When FRENIC-Multi Series (including FRENIC-Mini Series, these inverters make it possible to save space through their FRENIC-Eco Series and 11 Series) is used, the built-in resistor...
  • Page 6 Fully compatible with network operation RS-485 communications (connector) is standard! Wiring is easy with the RS-485 communications card (optional)! A connector (RJ-45) that is compatible with RS-485 The RS-485 communications card is also available as an communications is standard equipment (1 port, also used for option.
  • Page 7 Variation Model List Semi-standard type Standard type EMC filter built-in type Applicable motor Three-phase Three-phase Single-phase Three-phase Three-phase Single-phase rating (HP) 230V 460V 230V 230V 460V 230V FRNF12E1S-2U FRNF12E1S-7U FRNF12E1E-2U FRNF12E1E-7U FRNF25E1S-2U FRNF25E1S-7U FRNF25E1E-2U FRNF25E1E-7U FRNF50E1S-2U FRNF50E1S-4U FRNF50E1S-7U FRNF50E1E-2U FRNF50E1E-4U FRNF50E1E-7U FRN001E1S-2U FRN001E1S-4U...
  • Page 8: Specifications

    Specifications ●Standard type ■Three-phase 230V (1/8 to 20HP) Item Specifications Type (FRN E1S-2U) Applicable motor rating [HP] (*1) Rated capacity [kVA] (*2) Three-phase 200V to 240V (with AVR function) Rated voltage [V] (*3) Rated current [A] (*4) (0.7) (1.4) (2.5) (4.2) (7.0) (10)
  • Page 9 ●Semi-standard type EMC filter built-in type ■Three-phase 230V (1/8 to 20HP) Item Specifications Type (FRN E1E-2U) Nominal applied motor [HP] (*1) Rated capacity [kVA] (*2) 0.30 0.57 Rated voltage [V] (*3) Three-phase 200 to 240V (with AVR) Rated current [A] (*4) (0.7) (1.4) (2.5)
  • Page 10: Common Specifications

    Specifications ●Common specifications Related Item Explanation Remarks function code 25 to 400Hz variable setting Maximum frequency 25 to 400Hz variable setting Base frequency Starting frequency 0.1 to 60.0Hz variable setting, Duration: 0.0 to 10.0s F23,F24 Carrier frequency 0.75 to 15kHz variable setting Frequency may drop automatically to protect the inverter depending on environmental temperature and output current.This protective...
  • Page 11 Related Item Explanation Remarks function code PID control Control with PID regulator or dancer controller. E61 to E63 J01 to J06 ■ Process command J10 to J19 • Key operation ( keys) : 0 to 100% : 0 to ±10V DC/0 to ±100% •...
  • Page 12: External Dimensions

    External Dimensions ●Inverter outline (standard type) Fig. a Fig.b 0.26 6.5) 0.26 6.5) 0.26(6.5) 0.26(6.5) 0.24(6) 0.28(7) (elongated hole) (elongated hole) Name plate Name plate Fig. c Fig. d 0.26(6.5) 0.26(6.5) 0.24(6) 0.24(6) 0.28(7) (elongated hole) Name plate 0.2(5) 0.2(5) Name plate Fig.
  • Page 13 Dimensions [Unit: inch (mm)] Power supply Inverter type Fig. voltage FRNF12E1S-2U 3.62(92) 0.39(10) FRNF25E1S-2U 4-0.20x0.24 (4-5x6) 3.15(80) 2.64(67) 4.72(120) 4.33(110) 3.23(82) FRNF50E1S-2U 4.21(107) 0.98(25) (elongated hole) FRN001E1S-2U 5.20(132) 1.97(50) FRN002E1S-2U 4-0.20x0.28 (4-5x7) Three-phase 4.33(110) 3.82(97) 5.12(130) 4.65(118) 5.91(150) 3.39(86) 2.52(64) FRN003E1S-2U (elongated hole) 230V...
  • Page 14 External Dimensions ●Inverter outline (EMC filter built-in type) Fig. g Fig. h 0.26(6.5) 2.64(67) 0.26(6.5) 0.26(6.5) 3.82(97) 0.26(6.5) 4-0.2x0.24(4-5x6) 4-0.2 4-5 x 7) (elongated hole) (elongated hole) 0.39(10) 2.36(60) 0.41(10.5) 3.5(89) Fig. i Fig. j 5.91(150) 2.17(55) 0.24(6) 5.04(128) 0.24(6) 1.08(27.5) 2- 0.2(2- 5) ( 6.5)
  • Page 15 Dimensions [Unit: inch (mm)] Power supply voltage Inverter type Fig. FRNF12E1S-2U 4.41 0.39 0.83 FRNF25E1S-2U 3.15 4.72 6.69 (112) 4.02 (10) (21.2) FRNF50E1S-2U (80) (120) (170) 5.00(127) (102) 0.98(25) 1.43(36.2) FRN001E1S-2U 5.98(152) 1.97(50) 2.41(61.2) FRN002E1S-2U FRN003E1S-2U 5.51 7.09 9.65 7.64 5.12 2.52 3.37...
  • Page 16: Keypad Operations

    Keypad Operations ■ Keypad switches and functions LED monitor Unit display When the motor is running or stopped: The unit of the data displayed at the LED monitor is indicated. Use the key to switch the displayed data. The monitor displays speeds, such as output frequency, set frequency, motor speed and load shaft speed, output voltage, Operation mode display output current, and power consumption.
  • Page 17: Basic Wiring Diagram

    Basic Wiring Diagram ●Wiring diagram The following diagram is for reference only. For detailed wiring diagrams, refer to the instruction manual. ■ Keypad operation ■ Run/Stop operation and frequency setting on the keypad (Note 1) P(+) (CM) (THR) (Note 4) [Wiring procedure] (Note 2) (1) Wire the inverter main power circuit.
  • Page 18: Terminal Functions

    Terminal Functions ■ Terminal Functions Related Symbol Terminal name Functions Remark function code L1/R,L2/S,L3/T Power input Connect a three-phase power supply. U,V,W Inverter output Connect a three-phase motor. For DC REACTOR P1,P (+) Connect the DC reactor (DCR). P (+),DB For braking resistor Connect the braking resistor (option).
  • Page 19 ■ Terminal Functions Related Symbol Terminal name Functions Remark function code Analog monitor (FMA) A monitor signal of analog DC voltage between 0 to +10V DC) can be output Connectable impedance (Minimum impedance: F29 to for the item selected from the following: 7.5HP(5kW) In the (0 to +10V DC) •...
  • Page 20: Main Circuit Terminals

    Terminal Functions ■ Terminal Arrangement ●Main circuit terminals Power Applied Fig. A Inverter type Fig. source motor [HP] Three- FRNF12E1 -2U phase P (+) N (-) L1/R L2/S L3/T FRNF25E1 -2U 230V Fig. A FRNF50E1 -2U FRN001E1 -2U FRN002E1 -2U FRN003E1 -2U Fig.
  • Page 21: Protective Functions

    Protective Functions Protective Alarm output Related Description Functions indication (30A, B, C) Note) function code ● During acceleration Overcurrent protection The inverter is stopped for protection against overcurrent. During deceleration Short circuit protection The inverter is stopped for protection against overcurrent caused by a short circuit in the output circuit. Grounding fault The inverter is stopped upon start-up for protection against overcurrent caused by a grounding fault in the output circuit.
  • Page 22: Function Settings

    Function Settings ■ Function Settings ●F codes: Fundamental Functions Func. Default Data Name Data setting range Min. Unit copy * Code setting 0: Disable both data protection and digital reference protection Data Protection 1: Enable data protection and disable digital reference protection 2: Disable data protection and enable digital reference protection 3: Enable both data protection and digital reference protection keys on keypad...
  • Page 23 ●F codes: Fundamental Functions Func. Default Data Name Data setting range Min. Unit copy * Code setting Current Limiter (Mode selection) 0: Disable (No current limiter works.) 1: Enable at constant speed (Disable during ACC/DEC) 2: Enable during ACC/constant speed operation (Level) 20 to 200 (The data is interpreted as the rated output current of the inverter for 100%.) Electronic Thermal...
  • Page 24: Functions Settings

    Functions Settings ■ Functions Settings ●E codes: Extension Terminal Functions Func. Data Name Data setting range Min. Unit Default setting Code copy 0.01 to 10.00 0.01 0.10 Frequency Arrival Delay Time 0.0 to 10.0 Frequency Arrival (hysteresis width) 0.0 to 400.0 60.0 Frequency Detection (FDT) (Detection level)
  • Page 25 ●E codes: Extension Terminal Functions Func. Data Name Data setting range Min. Unit Default setting Code copy 42 (1042) : Position control limit switch [LS] 43 (1043) : Position control start/reset command [S/R] 44 (1044) : Serial pulse Receive mode [SPRM] 45 (1045) : Position Control return mode...
  • Page 26 Functions Settings ■ Functions Settings ●P codes: Motor Parameters Func. Data Name Data setting range Min. Unit Default setting Code copy Motor 1 (No. of poles) 2 to 22 Pole Y1Y2 (Rated capacity) 0.01 to 30.00 (where, P99 data is 0, 3, or 4.) 0.01 Y1Y2 Rated capacity...
  • Page 27 ●H codes: High Performance Functions Func. Data Name Data setting range Min. Unit Default setting Code copy UP/DOWN Control 0 : 0.00 (Initial frequency setting) 1 : Last UP /DOWN command value on releasing run command Low Limiter (Mode selection) 0 : Limit by F16 (Frequency limiter: Low) and continue to run 1 : If the output frequency lowers less than the one limited by F16 (Frequency limiter: Low), decelerate to stop the motor.
  • Page 28 Functions Settings ■ Functions Settings ●A codes: Motor 2 Parameters Func. Data Name Data setting range Min. Unit Default setting Code copy (No. of poles) 2 to 22 Pole Y1Y2 Motor 2 (Rated capacity) 0.01 Y1Y2 0.01 to 30.00 (where, P99 data is 0, 3, or 4.) 0.01 0.01 to 30.00 (where, P99 data is 1.) (Rated current)
  • Page 29 ●J codes: Application Functions Func. Data Name Data setting range Min. Unit Default setting Code copy (the start timer) 0.0 to 1000.0 Position control (Start point: MSD) -999 to 999 (Start point: LSD) [P], 0 to 9999 (Position preset: MSD) -999 to 999 (Position preset: LSD) [P], 0 to 9999...
  • Page 30 Functions Settings ■ Functions Settings ●o codes: Link Functions Func. Data Name Data setting range Min. Unit Default setting Code copy Command/feedback input (Input form selection) 0, 1, 2, 10, 11, 12, 20, 21, 22 0.01 to 200.00 Speed control (P item) 0.01 10.00...
  • Page 31 Peripheral Equipment Connection Diagrams Remote keypad (Standard equipment) Extension cable for Inverter loader software for Windows If the back cover packed with the inverter is mounted remote operation This software is used to set function codes in the Model Length[ft(m)] and the extension cable is used, remote operation inverter from a personal computer, to manage data, etc.
  • Page 32: Braking Resistor

    Options ■ Options Braking resistor Type, specifications and external dimensions [Unit: inch(mm)] Voltage Dimensions [Unit: inch (mm)] Mass [Standard type] (DB -2) (DB 230V series 460V series [lbs(kg)] [10% ED type] (DB -2C) (DB -4C) DB0.75-2 DB0.75-4 2.52(64) 12.20(310) 11.61(295) 2.64(67) 2.9(1.3) Standard...
  • Page 33 DC REACTOR Power Applicable Dimensions Unit: inch (mm) Mass REACTOR supply motor rating Inverter type [lbs (kg)] type voltage [HP] Terminal Mounting hole hole FRNF12E1 -2U 0.20x0.31 DCR2-0.2 2.60(66) 2.20(56) 3.54(90) 2.83(72) 0.20(5) 3.70(94) 1.8(0.8) (5.2x8) FRNF25E1 -2U FRNF50E1 -2U DCR2-0.4 2.60(66) 2.20(56)
  • Page 34 Options ■ Interface card RS-485 communication card (OPC-F1-RS) Built-in type DeviceNet card (OPC-E1-DEV) Front installation type Connection with a host (master) device such as PC or PLC allows you Connection with the DeviceNet master unit permits application to to control FRENIC-Multi as a subordinate (slave) device. (The card is the system that requires operation commands and frequency added to the RS-485 communication devices for FRENIC-Multi.) settings.
  • Page 35 ■ External cooling attachment External cooling attachment (PB-E1-7.5/PB-F1-15) This attachment allows installation of the inverter heat sink outside the panel. With this attachment, it is possible to improve the cooling effect and to make the panel more compact. 3.88(98.5) 3.80(96.5) 10.31(262) 7.56(192) 3.19(81)
  • Page 36 Options ■ Devices requiring wiring Recommended cable size (mm Magnetic contactor (MC) MCCB, GFCI Power Applicable rated current (A) Main power input supply motor rating Input circuit Inverter type Inverter For connection DC Reactor (L1/R, L2/S, L3/T) DC Reactor Output voltage (HP) output...
  • Page 37: Warranty

    Warranty To all our customers who purchase Fuji Electric FA Components & Systems' products: Please take the following items into consideration when placing your order. When requesting an estimate and placing your orders for the products included in these materials, please be aware that any items such as specifications which are not specifically mentioned in the contract, catalog, specifications or other materials will be as mentioned below.
  • Page 40 NOTES lubricated gearbox or speed changer/reducer, then not use power factor correcting capacitors in the When running general-purpose motors continuous motor operation at low speed may inverter output circuit (secondary). An overcurrent cause poor lubrication. Avoid such operation. trip will occur, disabling motor operation. •...

Table of Contents