FujiFilm Frenic-Mini Instruction Manual page 140

Controller
Table of Contents

Advertisement

Check part
Filtering
1) Check for electrolyte
capacitor
(Note 1)
2) Check if the safety valve
3) Measure the capacitance if
Braking
1) Check for odor caused by
resistor
2) Check for broken wire.
Transformer
Check for abnormal roaring
and reactor
noise and odor.
Magnetic
1) Check for chatters during
contactor
and relay
2) Check for rough contacts.
Printed
1) Check for loose screws and
circuit board
(Note 1)
2) Check for odor and
3) Check for cracks, breakage,
4) Check the capacitors for
Cooling fan
1) Check for abnormal noise
(Note 1)
2) Check for loose bolts.
3) Check for discoloration
Ventilation
Check the heat sink, intake and
path
exhaust ports for clogging and
foreign matter.
(Note 1) The judgement level of part replacement period with Menu #5 "Maintenance information" should
be used as a guide. Determine the replacement period on the basis of the standard replacement years.
(See Section 7.5 "List of Periodical Replacement Parts.")
If the inverter is stained, wipe it off with a chemically neutral cloth to remove dust, use a vacuum
cleaner.
Table 7.1 Continued
Check item
leakage, discoloration,
cracks and swelling of the
case.
does not protrude
remarkably.
necessary.
overheat and cracked
insulator.
operation.
connectors.
discoloration.
deformation and remarkable
rust.
electrolyte leaks and
deformation.
and excessive vibration.
caused by overheat.
How to inspect
1),2)
Visual inspection
3) Measure
discharge time
with capacitance
probe.
1) Smelling and
visual inspection
2) Visual inspection
or measurement
with multimeter
under
disconnection of
one lead
Hearing, visual and
smelling inspection
1) Hearing
inspection
2) Visual inspection
1) Retighten.
2) Smelling and
visual inspection
3), 4)
Visual inspection
1) Hearing and visual
inspection, or turn
manually (be sure
to turn the power
off).
2) Retighten.
3) Visual inspection
Visual inspection
7-3
Evaluation criteria
1),2)
No abnormalities
3) The discharge
time is not shorter
than time
specified by the
replacement
manual.
1) No abnormalities
2) Within ± 10% of
displayed
resistance
No abnormalities
1), 2)
No abnormalities
1), 2), 3), 4)
No abnormalities
1) Smooth rotation
2), 3)
No abnormalities
No abnormalities