FujiFilm Frenic-Mini Instruction Manual page 40

Controller
Table of Contents

Advertisement

Symbol
Name
[FMA]
Analog
The monitor signal for analog DC voltage (0 to +10 VDC) is output. The
monitor
signal functions can be selected from the following with function code F31.
- Output frequency (before slip compensation)
- Output frequency (after slip compensation)
- Output current
- Input power
- DC link circuit voltage
*Input impedance of external device: Max. 5 kτ
[11]
Analog
Common terminal for analog input and output signals
common
This terminal is electrically isolated from terminals [CM] and [Y1E].
[Y1]
Transistor
(1) Various signals such as inverter running, speed/freq. arrival and over-
output
(2) Switches the logic value (1/0) for ON/OFF of the terminals between
Digital input circuit specification
[PLC]
Transistor
Power source of +24 VDC to be fed to the transistor output circuit load.
(P24)
output
To enable the source, it is necessary to short-circuit between terminals
power
[Y1E] and [CM].
[Y1E]
Transistor
Common terminal for transistor output signal
output
This terminal is electrically Isolated from terminals [CM] and [11].
common
Table 2.8 Continued
load early warning can be assigned to the terminal [Y1] by setting
function code E20. Refer to Chapter 5, Section 5.2 "Overview of Func-
tion Codes" for details.
[Y1] and [Y1E]. If the logic value for ON between [Y1] and [Y1E] is 1 in
the normal logic system, for example, OFF is 1 in the negative logic
system and vice versa.
- Check the polarity of the external power inputs.
- When connecting a control relay, first connect a surge-
absorbing diode across the coil of the relay.
2-19
Functions
- Output voltage
- PID feedback amount
- Analog output test voltage (+)
Item
ON level
Operation
voltage
OFF level
Maximum load current
at ON
Leakage current at OFF
Max.
2V
27V
50mA
0.1mA

Advertisement

Table of Contents
loading

Table of Contents