High Performance, Multifunction Inverter
About this document
This manual, a supplement for the FRENIC-MEGA series of inverters having a ROM version 3600 or later, contains addition,
modification, and correction to the FRENIC-MEGA Instruction Manuals (INR-SI47-1183b-E, INR-SI47-1223c-E,
INR-SI47-1334-E, and INR-SI47-1335a-E). For other descriptions, refer to the original manuals.
Checking the inverter's ROM version
The inverter's ROM version can be checked on Menu #5 "Maintenance Information" (
detailed keypad operation, refer to the inverter original manuals.
About newly added functions
The functions listed below are newly added to the FRENIC-MEGA series of inverters having a ROM version 3600 or later.
For details about those functions, refer to Section 2 "Details of Function Codes Added" or the PG Interface Card Instruction
Manual.
Inverter's ROM Version
3600 or later
The PG interface card OPC-G1-PG22 is applicable to inverters having a ROM version 3510 or later.
Icons
The following icons are used throughout this manual.
This icon indicates information which, if not heeded, can result in the inverter not operating to full efficiency, as well
as information concerning incorrect operations and settings which can result in accidents.
This icon indicates a reference to more detailed information.
Fuji Electric Systems Co., Ltd.
(Supplement to Instruction Manual)
(1) Online tuning
Performs tuning while the motor is rotating in order to cover the motor speed
fluctuation caused by the temperature rise of the motor.
(2) Function extension of brake signal
Extends the brake-ON sequence function.
(3) PG error processing
Changes the PG error detection width if the speed command exceeds the base
frequency.
(4) Synchronous operation
Enables synchronous operation of two motors equipped with a pulse generator
(PG). The PG interface card (OPC-G1-PG or OPC-G1-PG22) is required. For
details, refer to the PG Interface Card Instruction Manual.
(5) Motor magnetic flux weakening control under "vector control without speed
sensor"
Improves the torque control stability. The overspeed detection level can be
specified.
(6) Improved regenerative power control under vector control
Adjusts the motor magnetic flux level to be applied during deceleration under
vector control.
(7) Terminal command "Enable battery operation" BATRY
(Function code data = 59)
Cancels the undervoltage protection so that the inverter under an undervoltage
condition runs the motor with battery power.
(8) "0 to 20 mA" range added to analog input/output
(9) Speed limit level adjustable with analog inputs under torque control
1
5
_
14
Newly Added Functions
) as a 4-digit code. For the
INR-SI47-1544-E