Single-Phase 200 V Class Series; Standard Models; Chapter 8 Specifications - FujiFilm FVR-Micro Instruction Manual

Advanced simple inverter
Table of Contents

Advertisement

Chapter 8
SPECIFICATIONS

8.1 Standard Models

8.1.1 Single-phase 200 V class series

Item
Type
Applicable motor rating (kW)
*1
Rated capacity (kVA)
*2
Rated voltage (V) *3
Rated current (A) *4
Overload capability
Rated frequency (Hz)
Phases, voltage,
frequency
Voltage and
frequency variations
Rated
current (A)
*6
Required power
supply capacity (kVA)
*7
Torque (%) *8
DC braking
Braking transistor
Applicable safety standards
Enclosure
Cooling method
Mass (kg)
*1 Fuji 4-pole standard motors
*2 Refers to the rated capacity assuming the rated output voltage as 220 V.
*3 Output voltages cannot exceed the power supply voltage.
*4 The load shall be reduced so that the continuous operating current is the rated current in parentheses or less if
the carrier frequency is set to 3 kHz or above or the ambient temperature exceeds 40°C.
Interphase voltage unbalance (%) =
*5
If this value is 2 to 3%, use an optional AC reactor (ACR).
*6 Refers to the estimated value to apply when the power supply capacity is 500 kVA (inverter capacity x 10 when
the inverter capacity exceeds 50 kVA) and the inverter is connected to the %X = 5% power supply.
*8 Refers to the average braking torque to apply when the motor running alone decelerates from 60 Hz with the
AVR control being OFF. (It varies with the efficiency of the motor.)
*9 Available only for induction motor drive.
0.4
0.4
0.9
Three-phase, 200 to 240 V (with AVR function)
3.5 (2.5)
150% of rated output current for 1 min (for the rated current given in
parentheses)
50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz
Voltage: +10 to -10%, Frequency: +5 to -5%
(w/o
DCR)
5.4
0.7
Braking starting frequency*9: 0.0 to 60.0 Hz,
Braking time: 0.0 to 30.0 s, Braking level: 0 to 100%
UL61800-5-1, IEC 61800-5-1(under application)
IP20 (IEC 60529), UL open type (UL50)
0.6
Max. voltage (V) - Min.voltage (V)
3 - phase average voltage (V)
Specifications
0.75
0.75
1.6
4.2 (4.2)
9.7
1.3
100
Built-in
Fan cooling
0.6
× 67 (Refer to IEC 61800 - 3)
8-1
1.5
2.2
1.5
2.2
2.8
3.8
9.2 (7.5)
10.0 (10.0)
16.4
24.0
2.4
3.5
50
30
1.0
1.0

Hide quick links: