Grid-connected pv inverter

Advertisement

Quick Links

Grid-connected PV Inverter
FU-SUN-15K-G03
User Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the FU-SUN-15K-G03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FujiFilm FU-SUN-15K-G03

  • Page 1 Grid-connected PV Inverter FU-SUN-15K-G03 User Manual...
  • Page 2 1. Introduction - 01 - ………………………………………………………… 1.1 Appearance Introduction - 01 - ………………………………………… 1.2 Parts list - 02 - ………………………………………………………… 2. Safety warnings and instructions - 03 - ……………………………………… 2.1 Safety signs - 03 - ………………………………………………………… 2.2 Safety instructions - 03 - …………………………………………………...
  • Page 3: About This Manual

    About This Manual How to Use This Manual Contents may be periodically Photovoltaic Grid-connected System PV array Inverter Metering Power grid Family load On-grid inverter can convert solar panel DC power into AC power which can directly input to the grid. Its appearance is shown below.These models contain SUN-15K-G03.
  • Page 4 1.2 Parts list : Normal Alarm screws M4×12 DC power connectors bolt M6×80 User Three-Phase Smart Meter manual - 19 - - 20 - - 02 -...
  • Page 5 2.1 Safety signs Warning: Shock Hazard: Safety Hint: High Temperature Hazard: Warning: of the country or local area. Warning: Otherwise it will damage the inverter. Shock Hazard: - 03 -...
  • Page 6 Shock Hazard: Shock Hazard: High Temperature Hazard: ℃ Please do not touch the inverter case. 2.3 Notes for using connect the inverter to the grid. 6. Please install where children can not touch. disconnect the DC side. - 04 -...
  • Page 7 3.1 Interface View Normal Alarm Pic 3.1 Front panel display 3.2 Status Indicator There are four LED status indicator lights in the front panel of the inverter. Please see table 3.1 for details. status Inverter detects DC input ●DC Low DC input voltage Grid Connected ●AC Grid Unavailable...
  • Page 8 Down Enter 3.4 LCD Display - 06 -...
  • Page 9 sunlight or raining. ℃. - 07 -...
  • Page 10 each inverter must be at least 500mm above and below.And must install the inverter at the place where children cannot touch. Please see picture 4.3. indicator status clearly. Safety Hint: ≤15 ° - 08 -...
  • Page 11 ≥500mm ≥500mm Anchoring Stainless steel screws Inverter - 09 -...
  • Page 12 move. - 10 -...
  • Page 13 2. Switch the DC lsolator OFF. 3. Assemble PV input connector to the inverter. Safety Hint: cause serious damages to the inverter. Safety Hint: Safety Hint: within the 1000V of the inverter. Safety Hint: Please use approved DC cable for PV system. (mm )...
  • Page 14 Pic 5.3 Disassemble the connector cap nut Pic 5.4 Crimp the contact pin to the wire Pic 5.5 connector with cap nut screwed on - 12 -...
  • Page 15 shown as picture 5.6 Warning: panel needs to be blocked by the opaque material and the DC switch should Warning: Use the DC power connector of the accessories. Do not interconnect the Warning: Cable CSA Max cable length Outside cable SUN-15K-G03 20-25mm - 13 -...
  • Page 16 1. Matching socket 2.Sleeve 3.Sealing core 4.Sealing nut Pic 5.7 AC connector structure , 40mm 8~15mm Pic 5.8 Strip AC cable Warning: - 14 -...
  • Page 17 - 15 -...
  • Page 18 all PE cables of the inverter need to be connected to the same grounding copper platoon to picture 5.11. Warning: - 16 -...
  • Page 19 prevent overcurrent. See table 5.3 below. SUN-15K-G03 21.8 Phone GPRS Router Web Server WIFI - 17 -...
  • Page 20: Startup And Shutdown

    6. Startup and Shutdown that the two inputs be connected to the same number of photovoltaic modules. - 18 -...
  • Page 21 6.1 Start up the inverter : 1. First switch on the AC breaker. crystal will show that the inverter is self-checking. NORMAL indicator light is on. 6.2 Inverter Shutdown connector. The inverter will close the LCD and all LED within two minutes. Inverter runs when connected to AC.
  • Page 22 are the interface between three sets of current sensor and one set of control terminals. SUN limiter will collect voltage and current from these interfaces and send control signals to the inverter. L1(L)L1(K)L2(L)L2(K)L3(L)L3(K) Pic 7.1 SUN Limiter view - 20 - - 20 -...
  • Page 23 of the AC switchis determined by the load capacity.The AC switch we recommend to connect to the inverter output refer to Table 5.2. L1(L) Solar panels L1(K) L2(L) L2(K) L3(L) L3(K) Limiter Normal Alarm Control signal Normal Alarm Distribution Box Control signal Load Pic 7.2 Wiring diagram...
  • Page 24 Load Pic 7.3 Clamp Senor Pic 7.4 Clamp Senor internal arrow the same on the waterproof terminal of the inverter. Twist the waterproof terminal and connect the terminal to the interface of the SUN limiter. The other side of the line should be connected to the control terminal.
  • Page 25: System Param

    Pic 7.7 Connect terminal to inverter 1. Turn on the AC switch << Meter System Param Param Limiter 0FF << Pic 7.9 Limit switch be completed. Shown as picture 7.10. - 23 -...
  • Page 26 Meter Utility Power: Limiter ON << chapter 7.9. to connect the energy meter. switch are determined by the power of load. connect the DC switch. The voltage and current of the switch depend on the PV array you access. - 24 -...
  • Page 27 1 2 3 4 5 6 7 8 Eastron (1,2,3,4) (5,6,7,8) B A G RS 485 RS 485 B RS 485 A Pic 7.11 Eastron meter Eastron SDM630-Modbus V2 Inverter Solar Panel array RS232/ 485 RS485 limiter AC Breaker RS 485 Male connector Family load...
  • Page 28 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron 15 16 17 18 19 20 1 2 3 4 Grid voltage Auxiliary Current inputs sampling power supply 14 13 12 RS 485 RS 485 A RS 485 B...
  • Page 29 Three-Phase Smart Meter (1,4,7,10) (3,6,9,10) RS 485 Pic 7.14 CHINT meter CHINT DTSU666 Inverter RS232/ 485 Solar Panel array RS485 limiter AC Breaker RS 485 Male connector Family load L1 L2 L3 N VCC_5V 485_B RS 485 Female connector Three-Phase Smart Meter meter 485_A L1 L2 L3 N...
  • Page 30: Meter Power

    1. Turn on the AC switch. picture 7.14. << Island System Param Param Meter 0FF << Pic 7.14 Meter switch Meter Power: - 28 -...
  • Page 31 Warning: inverter more responsive to limit the power. Safety Hint: (when using SUN limiter, the arrow of current sensor points to the load) High Temperature Hazard: cannot able to normal operate. grid( feed into grid) But please don’t setup “Meter ON” - 29 -...
  • Page 32 - 30 -...
  • Page 33 inverter. LCD Main menu Total DC Power Device PV1 and Power UA and UB Fault record UC and Freq E-Day and E-Total Start System param Time *Meter Running param Setup *ImpEp and Total * PV VA *Load Comm. param *LoadEp and Total successfully.
  • Page 34 Power: Power: State: Standby State: Com.Error inverter temperature. Total DC POWER: PV1: 0.0V 0.0A Power: Pic 8.3 PV input voltage and current Pic 8.4 Load power UA: 234V 0.0A 0V 0.0A 0V 0.0A Freq: 0.00Hz Pic 8.6 Grid voltage and frequency 21 - 05 - 2020 Meter 15 : 57 : 08...
  • Page 35 LoadEp: 0.00KWh Total : 0.00KWh E-Day : E-Total : 134KWh 8.2 Submenus in the Main Menu Device Info. << GL3000 SN-01 Fault Record ID:2222224332 ID:2222224332 Inv1400 Inv1400 Lcd0235 on the error code. Device Info. 1 F35 220125 08 Fault Record << 2 F56 220124 20 Pic 8.14 Fault Record - 33 -...
  • Page 36 ON / OFF << Turn ON << Setup Turn OFF Turn ON Turn OFF << Cancel << Cancel Setup Branch 1 : 0.0A PV VA << Branch 2 : 0.0A Pic 8.16 PV String current Setup << System Param << PV VA Param Protect Param...
  • Page 37 Time Set << Display Set Language Set Factory Reset << Factory Reset Set Restore << Pic 8.18 System Param 20200522 OK English << Polski 08:11:21 Cancel Pic 8.19 Time Pic 8.20 Language Bright Keep << Polski P CCK << Delay time 05S Delay time 05S Confirm Reset <<...
  • Page 38 PassWord Pic 8.25 Password Vref 0.0V ActiveP ReactP 0.0% << Q-Mode OFF << Fun RCD OFF << -1.000 Fun ISO OFF << SelfCheck Island OFF << Limiter Feed-in 0% << Meter MPPT Num Pic 8.26 - 36 -...
  • Page 39 NAME 80-260V Vref ReactP Power Fator Fun_ISO Fun_RCD 0-1000s Self-check Island Meter set here to ON Limiter to ON It is used to deploy how much power can be WindTurbine WindTurbine OFF << CLR <- WindTurbine ON <- Pic 8.27 - 37 -...
  • Page 40 OF-Derate OFF <- OF-Derate HYS <- OF-Derate ON <- UF-Uprate OFF <- UF-Uprate HYS <- WGra 0.000% WGRa 0.000% UF-Uprate ON <- WGra 0.000% WGra 0.0% << WGraStr 0.0% PowerLim << LVRT HVRT OFF << Sunspec OFF << Sunspec OFF << Cancel <<...
  • Page 41 NAME OF-Derate frequency UF-Uprate frequency power response to grid voltage LVRT HVRT PowerLim Demand Response Modes Sunspec - 39 -...
  • Page 42 Over-frequency Response OFDMode HYS <- OF-Derate ON <- OF-Derate OFF <- Tab. 11-4 Definition of Over- frequency Response Parameters Range Parameter Description 45HZ-65HZ Fstr The Start frequency value for over-frequency response. Fstop 45HZ-65HZ The Stop frequency value for over-frequency response. In hysteresis mode, power is restored only when RecPT 45HZ-65HZ...
  • Page 43 Frec 50.10Hz RecDly 0.00 OK << Cancel RecGra 0.00% << The inverter provides a reactive power regulation function. Tap Reactive Power Regulation Mode to select proper regulation mode and set the corresponding parameters. ActiveP ActiveP Q-Mode Q(P) << Q-Mode OFF << ActiveP ActiveP Q-Mode PF(P) <<...
  • Page 44 "Q(U)" Mode "Q(P)" Mode The reactive power output by the inverter is controlled by the active power of the inverter. "PF(P)" Mode The PF is controlled by the active power of the inverter. “Q(U)” Mode ActiveP Pstart 0.0% << QMode Pstop Q(U) <-...
  • Page 45 (U1,Q1) Upper Q/Pn lnd (U2,Q2) (U4,Q4) Grid Voltage (U3,Q3) (U5,Q5) Lower Q/Pn Cap (U6,Q6) - 43 -...
  • Page 46 parameter Range descrption The QU mode starts when the active power Pstart 0%-130% Rate out power is greater than this value The QU mode stops when the active power Pstop 0%-130% Rate out power is less than this value Value of Q/Pn at point (U1,Q1) on the Q(U) -60% -60% Q/Pn mode curve Grid voltage limit at point (U1,Q1) on the...
  • Page 47 “Q(P)” Mode Upper Q/Pn lnd (P1,Q1) The reactive power output by the inverter is controlled by the active power of the inverter. P2(P2,Q2) P/Pn P4(P4,Q4) P3(P3,Q3) P5(P5,Q5) Lower P6(P6,Q6) Q/Pn Cap 0.0% << ActiveP 20.0% QMode QP <- 0.0% 0.0% << 0.0% <<...
  • Page 48 parameter Range descrption Value of Q/Pn at point (P1,Q1) on the Q(P) mode 0%-100% Pn curve Grid voltage limit at point (P1,Q1) on the Q(P) mode -60% -60% Q/Pn curve Value of Q/Pn at point (P2,Q2) on the Q(P) mode 0%-100% Pn curve Grid voltage limit at point (P2,Q2) on the Q(P) mode...
  • Page 49 8.5 Protect Param Note: Engineer Only. need to reset it. The password is same as 8.4 Running param PassWord GridStanderd << Advanced Pic 8.32 Password INMETRO EN50438 EN50549 << IEC61727 << CUSTOM UTE_C15 RD_1699 << VDE_4105 << CEI_0_21 AS4777(.2) G98_G99 <<...
  • Page 50 OverVolt OverVolt Point 240.0V << Delay 1000ms << UnderVolt UnderVolt Point 235.0V << Delay 1000ms << UnderVolt UnderVolt Point 235.0V << Delay 1000ms << UnderVolt UnderVolt Point 235.0V << Delay 1000ms << OverFreq OverFreq Point 52.00Hz << Delay 1000ms << OverFreq OverFreq Point...
  • Page 51 UnderFreq Lv2 UnderFreq Lv2 Point 48.00Hz << Delay 1000ms << UnderFreq Lv3 UnderFreq Lv3 Point 48.00Hz << Delay 1000ms << Reconnection Reconnection 0.0V << Udown 0.0V << Reconnection Reconnection 0.00Hz << Fdown 0.00Hz << OV 10 Minutes OV 10 Minutes Enable OFF <<...
  • Page 52 Warning: maintain. Warning: any parts of the inverter. - 50 -...
  • Page 53 10.1 Error code messages are listed Table 10.1. DC input polarity reverse fault Check the PV input polarity. Check the grounding cable of inverter. permanent fault DC leakage current fault Hardly appear the code. Never ever happened so far. Ground fault GFDI Read the memory error Write the memory error GFDI blown fuse...
  • Page 54 Check whether solar panel output current is within the allowed range. DC over current fault of the hardware Check if the inverter FW version is suitable for the hardware. installer or service. Hardly appear the code. Never ever happened so far. Contact your installer for help.
  • Page 55 AC grid phase error Hardly appear the code. Never ever happened so far. AC three-phase voltage unbalance Hardly appear the code. Never ever happened so far. failure AC three-phase current unbalance Hardly appear the code. Never ever happened so far. failure Check AC current sensor and its circuit.
  • Page 56 1. It tells the PV input voltage is low and it always happens in the early morning. DC busbar voltage is too low contact your installer or service. AC grid U over current Hardly appear the code. Never ever happened so far. AC grid V over current Hardly appear the code.
  • Page 57 Input Side 19.5 1000 200~850 Output Side 16.5 Three phase 21.7 23.9 41.4 46.0 Output Power Factor 0.8 leading~0.8 lagging Grid Current THD Grid Frequency Range 47-52 or 57-62( ) 333×472×202 Topology Transformerless -25 ~ 65℃ >45℃ IP65 Cooling Concept Smart cooling 2000m >20 Years...
  • Page 58 MC-4 mateable IP65 rated plug Display LCD1602 Interface - 56 -...