The procedure below describes how to reset the Mediant 1000 MSBG and Mediant 1000B
Gateway & E-SBC to default settings using the hardware reset button.
To restore Mediant 1000 MSBG and Mediant 1000B Gateway & E-SBC to factory
defaults:
With a paper clip or any other similar pointed object, press and hold down the reset
button (located on the CRMX module) for at least 12 seconds, but no longer than 25
seconds.

Figure 4-5: Reset Pinhole Button on Mediant 1000 MSBG Front Panel (CRMX Module)

Figure 4-6: Reset Pinhole Button on Mediant 1000B Gateway & E-SBC Front Panel