Flame Calibration - Sit Nova 826 - Beech ovens REC Series Installation And Operation Manual

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)
Flame Calibration – Sit Nova 826
The following section explains the calibration procedure for the Sit Nova 826
Combination Gas valve. The valve allows for use with both Propane and Natural gas,
however the jet in the burner will need to be changed and the data plate updated when
converting gas types. Conversion kits are available to purchase from Beech Ovens
Head Office (sales@beechovens.com.au) or your local Beech Ovens representative.
Note: Never attempt to convert gas types without first changing the burner jet
and data plate in the Gas control cabinet.
Page 75
Confidential and Proprietary
28/07/2011 (C)