Tri-Electrode And Burner Maintenance; Tube Burner - Beech ovens REC Series Installation And Operation Manual

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)

Tri-Electrode and Burner Maintenance

The most common cause of erratic operation of the Gas system is that the Tri-
electrode and/or burner becomes contaminated by debris. This may be in the form of
foodstuffs or ash deposited in the area in which the Tri-electrode and/or burner
operates.
The following instruction shows the procedure for checking the position of the Tri-
electrode and removal of any debris which may become present around the Tri-
electrode and/or burner. Adjustment should generally not be necessary, though
cleaning is common as part of regular maintenance.
Note: Be sure to turn off the power and Gas before any maintenance takes
place on the oven. Maintenance should be carried out when the oven is cold.

Tube Burner

To remove the Tube burner,
loosen and remove the burner
flange bolts (3-5 bolts).
Should the burner require
cleaning, remove the gas line
into the burner. This is a flared
connection and does not require
sealant.
Note: Be sure not to kink or
damage the Gas line whilst
handling the burner.
Clean, if required, by turning
upside down and blowing out
any debris that may have built
up in the burner nozzle.
In extreme cases, the burner
can be washed and scrubbed
with a brush. Use compressed
air for final clean.