Beech Ovens
RND-REC-RGO Manual (R1)
Low Flame
When the correct pressure is achieved for High Flame, set the Digital Temperature
controller so that the set point temperature (SV) is 12°C below the current oven
temperature (PV). This will cause the Combination Gas valve to switch to Low Flame
mode.
The Low Flame pressure setting can now be set to a recommended pressure of
0.375kPa for Natural Gas and 0.75kPa for Propane Gas.
Hold the position of the Brass nut in place with the 10mm spanner. With a No:1
Phillips head (star) screwdriver, adjust the Phillips head screw clockwise to
increase pressure and counter-clockwise to reduce pressure. (see above)
If it is found that the recommended setting is not functioning as desired, Low
Flame can be adjusted with the help of an observer to regulate the flame to a
satisfactory size. (This may be the case with multi-burner ovens, though the
recommended minimum pressures remain 0.375kPa for Natural Gas and
0.75kPa for Propane Gas.
Re-check the High Flame settings as outlined in High Flame.
When the settings are correct replace the Plastic cover.
Remove test gauge fitting (hose), replace the outlet pressure test point screw
and tighten to 2.5Nm.
Reset the Digital Temperature controller‟s set point temperature (SV) to the
required temperature. (Refer to Digital Temperature Controller for full
instructions.)
Page 78
Confidential and Proprietary
28/07/2011 (C)