Double Burner Installations

Most two (2) burner ovens use a Tube burner and a Display burner. The Display
burner is expected to be the primary burner and is connected to Zone 2 components.
This is done to ensure that the Tube burner will cycle between High Flame, Low Flame
and Off and the Display burner will cycle only between High Flame and Low Flame,
remaining on as a feature burner. (The display burner will turn off at around 400°C.)
To ensure that each burner is connected correctly each Burner, Combination Gas Valve
and Flame pack are labelled with corresponding zone numbers; Zone 1 and Zone 2. It is
critical that all Combination gas valves, Burners and Flame packs are connected to the
corresponding zone components.
If this labelling seems incorrect or there is confusion as to which burner should be
connected to which component, please contact Beech Ovens Technical Support for
assistance.
technical@beechovens.com.au
Zones 1 & 2
burner connection
points
Reticulated Gas supply
connection point
Page 57
Confidential and Proprietary
Display burner
(Zone 2)
28/07/2011 (C)
Tube burner
(Zone 1)