Protection Of Combustible Floors - Beech ovens REC Series Installation And Operation Manual

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)
If there are stairs, there must be sufficient width to install the ‟A‟ frame to move the
halves up the stairs. If there are too many stairs or the corridor has corners that are too
sharp, or the opening is narrower than 700mm, the oven cannot be installed without
modifications to the building. Seek special advice from Beech Ovens Technical
Support.
technical@beechovens.com.au
Investigation must be made to ensure that the floor both where the oven is to be
transported upon and the floor under where the oven shall be installed are sufficient to
support the oven.

Protection of Combustible floors

All Beech Ovens must be installed upon non-combustible material. The minimum hearth
extension areas to be covered with non-combustible material in relation to the door
opening of the oven shall cover at least the following areas:
 750 mm to each side of the door opening.
 900 mm in front of the door opening.
Combustible material
(e.g. Wood)
Non-Combustible
material
(e.g. Stainless Steel)
If you have an ash disposal container it must also be placed on non-combustible
material, have legs to raise it from floor contact and have a tight-fitting lid.