Beech ovens REC Series Installation And Operation Manual page 45

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)
The Gas control cabinet has the following internal components:
Data plate
NOTE: The Gas Control cabinet shown is a single burner system or Gas Back-up (GB)
control cabinet. The Full Gas (FG) control cabinet has double of some of these
components.
The Gas control cabinet will also contain some components required for installation
when delivered as seen here in the bottom of the cabinet.
The system is fitted with an emergency manual gas isolation valve located inside the
control cabinet. This is near the bottom of the cabinet and is prior to the Combination
Gas valve which also incorporates the pressure regulator and High and Low flame
adjustments.
See more information in the General Technical Details at the rear of this manual. A data
plate is also visible in the door of the oven gas control cabinet stating technical details
for the specific system.
Page 44
Confidential and Proprietary
Flame Pack
Thermocouple
Combination Gas Valve
Electrical Circuit Breaker
Manual Gas Isolation Valve
Power supply cord
Components for installation.
E.g. SS gas pipe and fittings.
28/07/2011 (C)