Troubleshooting Guide - Beech ovens REC Series Installation And Operation Manual

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)
To obtain the best results from your Beech Oven, please read the Installation and Operation Manual in it‟s entirety before operation. Should a fault or
complication arise, please read the following Troubleshooting guide to determine a possible source and solution to the problem.
If after having read this manual and followed the instructions in the Troubleshooting guide failed to resolve the problem, please contact Beech Ovens Technical
Support at
technical@beechovens.com.au
Note: Always ensure that both power and gas are turned off before any troubleshooting or maintenance is carried out. In addition to having the
Installation and Operation Manual in hand, Beech Ovens recommend the following tools as standard when troubleshooting: Approved Gas Pressure
gauge, Multimeter, Digital (or analogue) Temperature gauge and a standard range of hand tools including wrenches, pliers and screwdrivers.
The following guide is a list of the most common problems encountered when using a Beech Oven.
Problem / Symptom
1. Smell of gas near oven.
2. Burner fails to ignite – spark heard
(evident) at Tri-electrode.
tripped.
3. Burner fails to ignite – no spark
heard under the oven (at burner)

Troubleshooting Guide

Possible Cause
1.1 Possible gas leakage - Do NOT operate oven.
2.1 Gas supply problems. (For LPG, is tank near empty?)
2.2 Contamination on Tri-electrode – debris, etc.
2.3 Spark is shorting to metallic surface.
2.4 Tri-Electrode not in correct position or misaligned.
2.5 Air in Gas line.
2.6 Faulty Flame pack.
2.7 Faulty Gas valve(s).
2.8 Tri-electrode cables incorrectly fitted to Tri-electrode or flame pack
3.1 Gas supply problems. (For LPG, is tank near empty)
3.2 No power to control cabinet - circuit breaker in Gas Control cabinet
3.3 Tri-Electrode cables faulty/ connections dirty/ fallen off.
3.4 No power to Flame Pack.
3.5 Faulty Flame pack.
3.6 „SV‟ setting below „PV‟ on Digital Temperature Controller.
3.7 Faulty Thermocouple.
Page 129
1.1.1 Refer to Gas Systems Overview.
1.1.2 Turn off main gas supply at Manual Gas Isolation Valve in
Gas Control Cabinet. Contact service technician.
2.1.1 Check gas supply (Contact service technician).
2.2.1 Refer to Tri-electrode and Burner Maintenance.
2.3.1 Refer to Tri-Electrode/ Igniter Assembly.
2.4.1 Refer to Tri-electrode and Burner Maintenance.
2.5.1 Refer to Connection Procedures.
2.6.1 Replace Flame pack.
2.7.1 Replace Gas Valve(s).
2.8.1 Refer to Tri-Electrode/ Igniter Assembly.
3.1.1 Check gas supply (Contact service technician).
3.2.1 Check power supply. Refer to Gas Systems Overview.
3.3.1 Refer to Connection Procedures.
3.4.1 Check power supply.
3.5.1 Replace Flame pack.
3.6.1 Refer to Digital Temperature Controller.
3.7.1 Do NOT build fire on Thermocouple.
3.7.2 Replace Thermocouple.