Electrical Connection; Final Checks - Beech ovens REC Series Installation And Operation Manual

Hide thumbs Also See for REC Series:
Table of Contents

Advertisement

Beech Ovens
RND-REC-RGO Manual (R1)

Electrical Connection

The system will require the following earthed mains electricity supply;
 220-240 Volt (other voltages available by request)
 50Hz
 10 Amp
Within the Gas cabinet a power supply cable is supplied connected to an Australian
standard plug. Should your oven be installed outside of Australia, a common practice is
to purchase an adapter to suit your local socket configuration.
In some instances a new plug may be fitted to suit your local socket configuration, or
you may wish to hard-wire your system to an isolator. If these methods are used,
ensure to adhere to the following instruction.
NOTE: Power supply to the system is polarity sensitive. The following colour
codes MUST be adhered to for your system to operate.
 Brown = Active / Live
 Blue = Neutral / Common
 Green = Earth

Final Checks

1. Check all gas, mechanical and electrical connections to all equipment. Ensure
that the burner and shroud are firmly located.
2. Check gas flow logic, opening all relevant manual valves.
3. Proceed with start up procedure outlined in the Commissioning section of this
manual.