Control Board Removal And Installation - kozy heat SP-34-L Installation And Operation Manual

Direct vent gas fireplaces
Table of Contents

Advertisement

8.3 Control Board Removal and Installation

WARNING:
If
burner
and/or
use
appropriate
protection
to
personal
property
before
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING GASKET
(LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS
DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water, whether
field or factory
8.3.1 Control Board Removal
1.
Disconnect electrical power.
2.
Locate the manual valve installed by your qualified service
technician. Turn the manual valve clockwise to the OFF position.
3.
Open the control compartment access panel.
4.
Remove the safety barrier and glass frame assembly.
5.
Disconnect any optional control from the top and bottom
terminals on the gas valve OR unplug all components from
receptacle and disconnect all wiring harnesses attached to the
gas valve.
6.
Remove log set, lava rock, and panels (if installed).
7.
Remove the burner tube by sliding it to the left off of the burner
orifice.
8.
Remove the pilot shield.
9.
Remove and save (4) screws securing the back log plate.
10. Remove and save (4) screws securing the left and right front log
plates.
11. Remove and save (5) screws securing the heat shield.
12. Remove and save (10) screws securing control board to firebox
floor.
13. Lift the control board out of the firebox, being careful not to
damage the sealing gasket underneath.
8.3.2 Control Board Installation
1.
Place control board in the firebox, aligning the holes in the
control board with the holes in the firebox bottom.
VERIFY SEALING GASKET IS IN PLACE.
2.
Secure the control board with screws previously removed.
3.
Reinstall the heat shield using (5) screws previously removed.
4.
Reinstall the front log plates. There is 'L' etched into the left
log plate and 'R' etched into the right plate. Position the plates
correctly into the firebox and secure with (4) screws previously
removed.
5.
Reinstall back log plate (4) screws previously removed.
6.
Reinstall pilot shield.
7.
Reinstall the burner tube by sliding it to the right and positioning
the burner tube venturi over the burner orifice.
8.
Reinstall log set, lava rock, and panels (if installed).
9.
Reconnect any optional control wires to the top and bottom gas
valve terminals OR reconnect all wiring harnesses to the gas
valve. Plug all components into an electrical outlet.
10. Reinstall the glass frame assembly and safety barrier.
11. Set control compartment access cover panel back into position.
12. Turn the manual valve counterclockwise to the ON position.
13. Reconnect electrical power.
14. Verify proper log placement, operation of fireplace, and any
electrical components.
#SP-34 L & MV R.9 April 2022
pilot
have
been
burning,
to
avoid
burns
or
damage
removing
any
components.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Back Log Plate
Shield
Front Log Plates
FIREPLACE SETUP 35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-34-mv

Table of Contents