8.4 Control Board Removal and Installation

WARNING:
If
burner
and/or
use
appropriate
protection
to
personal
property
before
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING GASKET
(LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS
DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water, whether
field or factory made.
8.4.1 Control Board Removal
1.
Disconnect electrical power.
2.
Locate the manual valve installed by your qualified service
technician. Turn the manual valve clockwise to the OFF position.
3.
Remove the safety barrier and glass frame assembly.
4.
Disconnect any optional control from the top and bottom
terminals on the gas valve, OR unplug all components from
receptacle and disconnect all wiring harnesses attached to the
gas valve.
5.
Remove log set.
6.
Remove back log plate (3) screws.
7.
Remove burner assembly, (2) screws on each side.
8.
Remove the burner heat shield (2) screws, located at the back of
the firebox.
9.
Remove light kit housing (2) screws.
10. Remove and save (8) screws securing the control board.
11. Lift the control board out of the firebox, being careful not to
damage the sealing gasket underneath.
8.4.2 Control Board Installation
1.
Place control board in the firebox, aligning the holes in the
control board with the holes in the firebox bottom.
VERIFY SEALING GASKET IS IN PLACE.
2.
Secure the control board to the firebox using (8) screws
previously removed.
3.
Reinstall the light kit housing (2) screws.
4.
Reinstall the burner heat shield (2) screws.
5.
Reinstall burner assembly (2) screws.
6.
Reinstall back log plate (3) screws.
7.
Reinstall log set.
8.
Reconnect any optional control wires to the top and bottom gas
valve terminals, OR reconnect all wiring harnesses to the gas
valve. Plug all components into an electrical outlet.
9.
Reinstall the glass frame assembly and safety barrier.
10. Turn the manual valve counterclockwise to the ON position.
11. Reconnect electrical power.
12. Verify proper log placement, operation of fireplace, and any
electrical components.
46 FIREPLACE SETUP
pilot
have
been
burning,
to
avoid
burns
or
damage
removing
any
components.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
REMOVE BACK LOG PLATE (3) SCREWS
REMOVE BURNER ASSEMBLY (2) SCREWS
REMOVE BURNER HEAT SHIELD (2) SCREWS
REMOVE LIGHT KIT HOUSING (2) SCREWS
REMOVE CONTROL BOARD (8) SCREWS
Figure 8.4, Control Board Removal and Installation
#BAY-36-LE & MV R.11 April 2021