6.1.15 Ink Absorber Box, Ink Absorber Felts, and PF Encoder Disk

Note: Do not remove the ink absorber box unless it needs to be replaced.
Note: Once the main drain tube is removed from the ink absorber box for the replacement of the
ink absorber box, it will become unusable and new part will have to be put back in. Using the
removed tube again may result in an ink leakage.
(1) Pull out the main drain tube from the ink absorber box.
Note: Pinch the end of the main drain tube with a clip in order to prevent drained ink from
leaking and the machine from getting stained with leaked ink.
Note: Do not place the main drain tube that has been pulled out on the main PCB. If the
PCB is stained with leaked ink, wipe it off with a dry cloth.
(2) Pull the ink absorber box up and out of the lower cover.
(3) Immediately set a new ink absorber box. Then replace the tube; that is, pull it off the joint
on the rear of the maintenance unit and connect a new tube to the joint and new ink
absorber box as shown below.
Note: If the ink absorber box or its surroundings are stained with ink, wipe them off with a
cloth.
(4) Take the ink absorber felts (upper and lower) out of the lower cover.
Maintenance unit
Main drain tube
Viewed from the right
Assembling Notes:
• When connecting the main drain tube to the ink absorber box, take care not to connect it
at an angle. The tube connected at an angle comes off easily, resulting in ink leakage.
After connection, check that there is no ink leakage.
• If you replace the ink absorber box (without replacing the main PCB), you also need to
replace the flushing box (see
counters as specified in
Pull up the main drain tube from the joint
on the rear of the maintenance unit and
immediately connect a new one.
Main drain tube
Section
Chapter 7, Section
Ink absorber
box
Ink
absorber
felt
(upper)
Ink absorber
felt (lower)
Lower cover
6.1.16) and reset both the purge and flushing
7.5.
6-76
Correct
Main drain tube
Do not connect the main drain tube
at an angle.
Connect the tube all the way seated.
(6_70_mini9e)