Brother MFC990CW Service Manual page 460

Inljet mfc/dcp
Hide thumbs Also See for MFC990CW:
Table of Contents

Advertisement

• Selectors 2 and 3: Dual tone detection frequency in ICM recording (Not used.)
If the machine detects either of the frequencies set by these selectors in ICM recording, it
disconnects the line. For example, if these selectors are set to "0, 0," the machine
disconnects the line upon detection of 350 Hz or 440 Hz.
• Selector 4: Dual tone detection sensitivity in ICM recording (Not used.)
Setting this selector to "1" increases the tone detection sensitivity in ICM recording.
• Selectors 6 through 8: Break time length for flash function
These selectors set the break time length.
This setting is effective only when the flash function is selected for the Speed Dial key by
using the function switch.
Selector
No.
1
|
1st dial tone detection
3
Max. pause time allowable for
4
remote ID code detection
5
Busy tone detection in automatic
sending mode
6
Busy tone detection in automatic
7
receiving mode
8
Not used.
Note: Selectors 5 through 7 are not applicable in those countries where no busy tone detection
is supported.
WSW05
(1st dial tone and busy tone detection)
Function
App. 4-8
Setting and Specifications
No. 1 2 3
0 0 0
: 3.5 sec. WAIT
0 0 1
: 7.0 sec. WAIT
0 1 0
: 10.5 sec. WAIT
0 1 1
: 14.0 sec. WAIT
1 0 0
: 17.5 sec. WAIT
1 0 1
: 21.0 sec. WAIT
1 1 0
: 24.5 sec. WAIT
1 1 1
: Detection (Without WAIT)
0: 2 seconds
No. 5 6
0 0 : No detection
0 1 : Detection only after dialing
1 0 : No detection
1 1 : Detection before and after dialing
0: Yes
1: 1 second
1: No
sec.: second(s)
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents