Comtech EF Data SDM-100A Installation And Operation Manual page 176

Satellite modem
Table of Contents

Advertisement

Remote Control Operation
A–24
SDM-100A Satellite Modem
"APD_" command).
p43 = n, where 'n' is '0' (off) or '1' (on).
Parameter 44 (p44): ADPCM Subscriber/Trunk Emulation
(ref. "SBTR_" command).
p44 = n, where 'n' is '0' (Subscriber) or '1' (Trunk).
Parameter 45 (p45): ADPCM E & M Signal Type (ref.
"EMS_" command).
p45 = n, where 'n' is '1', '2', '3', '4', or '5' (signal type).
Parameter 46 (p46): ADPCM Encoding Law (ref. "LAW_"
command).
p46 = n where 'n' is 'A' (A-Law ) or 'U' (u-Law)
Parameter 47 (p47): Off hook alert enable (ref. "HOOK_"
command).
p47 = n, where 'n' is '0' (off) or '1' (on).
Parameter 48 (p48): ADPCM Transmit Service Channel
Level (ref. "ISCL_" command).
p48 = nnn, service channel level in dBm.
Parameter 49 (p49): ADPCM Receive Service Channel
Level (ref. "ISCL_" command).
p49 = nnn, service channel level in dBm.
Parameter 50 (p50): ADPCM RS-422 Send Data Signal
Programming (ref. "SD_" command).
p50 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 51 (p51): ADPCM RS-422 Receive Signal
Programming (ref. "RD_" command).
p51 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 52 (p52): ADPCM RS-422 Receiver Ready
Signal Programming (ref. "RR_" command).
p52 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 53 (p53): ADPCM RS-422 Data Mode Signal
Programming (ref. "DM_" command).
p53 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 54 (p54): ADPCM Audio Loopback Jumper
Status (ref. "ALBJ_" command).
p54 = n, where 'n' is '0' (off) or '1' (on).
Parameter 55 (p55): RTS TX-IF Control Mode (ref.
"RTSM_" command).
p55 = n, where 'n' is '0' (off) or '1' (on).
Parameter 56 (p56): ASYNC Communications
programming ON/OFF (ref. "ASP_" command).
p56 = n, where 'n' is '0' (off) or '1' (on).
Parameter 57 (p57): Interface Loop Timing (ref. "ILT_"
command).
p57 = n, where 'n' is '0' (off) or '1' (on).
Parameter 58 (p58): ASYNC TX Overhead Baud Rate (ref.
"TOBR_" command).
p58 = nnnnn, where 'nnnnn' is the currently
programmed baud rate.
Parameter 59 (p59): ASYNC TX Channel Char. Length (ref.
"TCCL_" command).
p59 = n, where 'n' is the currently programmed
character length.
Parameter 60 (p60): ASYNC TX Channel Stop Bits (ref.
"TCSB_" command).
p60 = n, where 'n' is the current number of stop bits
programmed.
Parameter 61 (p61): ASYNC TX Channel Parity (ref.
"TOCP_" command).
p61 = xxxx, where 'xxxx' is the currently programmed
parity.
Parameter 62 (p62): ASYNC RX Overhead Baud Rate (ref.
"ROBR_" command).
p62 = nnnnn, where 'nnnnn' is the currently
programmed baud rate.
Parameter 63 (p63): ASYNC RX Channel Char. Length
(ref. "RCCL_" command).
p63 = n, where 'n' is the currently programmed
character length.
Parameter 64 (p64): ASYNC RX Channel Parity (ref.
"ROCP_" command).
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 2)
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(Note 3)