Comtech EF Data SDM-100A Installation And Operation Manual page 174

Satellite modem
Table of Contents

Advertisement

Remote Control Operation
Bulk Consol
Command:
Status
Response:
A–22
<add/BCS_'cr'
>add/BCS_p1,p2,p3, . . . pn'cr''lf']
SDM-100A Satellite Modem
This command causes bulk modem status to be returned.
To reduce the length of the response, message parameter
data are returned without identifiers. However, parameter
identification can be determined by order of return. Each
status parameter is terminated with a ',' (comma) except for
the last parameter which has the standard message
termination sequence ('cr''lf']). Most of the data returned is
formatted the same way as the single command status
request (refer to the appropriate portions of this document
in preceding sections).
Where 'pn' is the last parameter returned.
Parameter 1 (p1): Modulator RF output (ref. "RF_"
command).
p1 = n, where 'n' is '0' (off) or '1' (on).
Parameter 2 (p2): Modulator IF frequency (ref. "MF_"
command).
p2 = nnn.nnnn, IF frequency in MHz.
Parameter 3 (p3): Modulator rate (ref. "MR_" command).
p3 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 4 (p4): Modulator preset 'A' assignment (ref.
"ARMA_" command).
p4 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 5 (p5): Modulator preset 'B' assignment (ref.
"ARMB_" command).
p5 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 6 (p6): Modulator preset 'C' assignment (ref.
"ARMC_" command).
p6 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 7 (p7): Modulator preset 'D' assignment (ref.
"ARMD_" command).
p7 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 8 (p8): Modulator preset 'V' assignment (ref.
"ARMV_" command).
p8 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 9 (p9): Modulator power offset (ref. "MPO_"
command).
p9 = snn.n, modulator power offset in dB.
Parameter 10 (p10): Modulator output power level (ref.
"MOP_" command).
p10 = snn.n, transmitter output power level in dBm.
Parameter 11 (p11): Scrambler enable (ref. "SE_"
command).
p11 = n, where 'n' is '0' (off) or '1' (on).
Parameter 12 (p12): Differential encoder enable (ref.
"DENC_" command).
p12 = n, where 'n' is '0' (off) or '1' (on).
Parameter 13 (p13): Modulator type (ref. "MT_" command).
p13 = n, where 'n' is '0' (EFD), '1' (INTL), '2' (CSC), '3'
(FDC), or 4 (SDM51).
Parameter 14 (p14): Modulator encoder type (ref. "MET_"
command).
p14 = n, where 'n' is '0' (SEQ) or '1' (VIT).
Parameter 15 (p15): Transmit BPSK Data Ordering (ref.
"TDA_" command).
p15 = n, where 'n' is '0' (NRM) or '1' (INV).
Parameter 16 (p16): Carrier only mode ON/OFF.
p16 = n, where 'n' is '0' (off) or '1' (on).
Parameter 17 (p17): Demodulator IF frequency (ref. "DF_"
command).
p17 = nnn.nnnn, demodulator IF frequency in MHz.
Parameter 18 (p18): Demodulator rate (ref. "DR_"
command).
p18 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Parameter 19 (p19): Demodulator preset A assignment
(ref. "ADRA_" command).
p19 = nnnn_mmm.mmm, code rate/data rate in kbit/s.
Rev. 0

Advertisement

Table of Contents
loading

Table of Contents