SDM-100A Satellite Modem
Automatic
Command:
Uplink
Response:
Power
Control
(AUPC)
Config
Status
Modem
Command:
Faults
Response:
Status
(Summary)
Modulator
Command:
Status
Response:
Demodulato
Command:
r Status
Response:
Interface
Command:
Transmit
Response:
Side Status
Interface
Command:
Receive
Response:
Side Status
Rev. 0
<add/ACS_'cr'
>add/ACS_'cr'
LPC_xxx'cr'
NOMP_-nn.n'cr'
MINP_-nn.n'cr'
MAXP_-nn.n'cr'
ENSP_n.n'cr'
MAXT_n.n'cr'
LCL_xxxx'cr'
RCL_xxxx'cr'
<add/MFS_'cr'
>add/MFS_'cr'
DMD_xxx'cr'
MOD_xxx'cr'
ITX_xxx'cr'
IRX_xxx'cr'
CEQ_xxx'cr''lf']
<add/MS_'cr'
>add/MS_'cr'
RF_xxx'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SFLT_xx'cr''lf']
<add/DS_'cr'
>add/DS_'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr'
SFLT_xx'cr''lf']
<add/ITXS_'cr'
>add/ITXS_'cr'
CLK_xxx'cr'
TAC_xxx'cr'
(See Note)
SFLT_xx'cr''lf']
<add/IRXS_'cr'
>add/IRXS_'cr'
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr'
RAC_xxx'cr'
(See Note)
DMXL_xxx'cr'
(See Note)
SFLT_xx'cr''lf']
Local AUPC Enable (ON/OFF)
Nominal Power Value (-5.0 to -30.0)
Minimum Power Limit (-5.0 to -30.0)
Maximum Power Value (-5.0 to -30.0)
E
/N
Target Set Point (3.2 to 9.7)
b
0
Max. Tracking Rate (0.5 to 6.0)
Local Carrier Loss (HOLD, NOM, MAX)
Remote Carrier Loss (HOLD, NOM, MAX)
The interface (AUPC) configuration status command causes a
block of data to be returned by the addressed modem. The
block reflects the current configuration of the interface.
Demodulator (FLT/OK)
Modulator (FLT/OK)
Interface Transmit Side (FLT/OK)
Interface Receive Side (FLT/OK)
Common Equipment (FLT/OK)
RF Output (ON/OFF) Actual Status Not Config
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Descrambler (OK/FLT)
BER Threshold (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Selected Transmit Clock Activity (OK/FLT)
Transmit Audio Clip (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Note: Status only returned when ADPCM board is installed.
Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Audio Clip (OK/FLT)
Demultiplexer Lock (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Note: Status only returned when ADPCM board is installed.
Remote Control Operation