Replacing The System Board - Fujitsu PRIMERGY TX100 S3 Maintenance Manual

Hide thumbs Also See for PRIMERGY TX100 S3:
Table of Contents

Advertisement

System board and components
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section
page
59.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section
BitLocker functionality" on page
14.3

Replacing the system board

Field Replaceable Units (FRU)
Average hardware task duration: 50 minutes
Average software task duration: 10 minutes
Note on network settings recovery
The following notes are required for TX100 S3p (PYT10Pxxx for Japanese
market).
I
When replacing network controllers or the system board, network
configuration settings in the operating system will be lost and replaced
by default values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing a
network controller or the system board.
Note on TPM
I
The system board can be equipped with an optional TPM (Trusted
Platform Module). This module enables third party programs to store key
information (e. g. drive encryption using Windows Bitlocker Drive
Encryption).
If the customer is using TPM functionality, the TPM has to be removed
from the defective system board and connected to the new system
board. For a detailed description, please refer to section
TPM" on page
304
"Connecting the server to the mains" on
82.
302.
Upgrade and Maintenance Manual
"Enabling
"Replacing the
TX100 S3

Advertisement

Table of Contents
loading

Table of Contents