R – Set Reference Point
Description
Th is command is used to move the reference point for the X- and
Y-axes. All horizontal and vertical measurements in other com-
mands use the setting for R as the origin for measurements.
Syntax
Rp
1
Parameters
p
1
p
2
Remarks
Th e reference point command is used to establish top and left
margins to prevent printing off the edge of the label. A minimum
margin of 1 mm should be used on all sides of the label.
Repeated printing outside the edge of the media can cause
excessive printhead wear.
For narrow labels, the R command could be substituted by a
q command, which has the benefi t of making better use of a
limited image buff er. However, the q command cannot aff ect the
vertical margin. Any R command after a q command will revoke
the latter.
Th e print direction commands ZB and ZT aff ect the location of
the reference point, as illustrated below:
Example
R50,100↵
Intermec EasyCoder ESim v4.20—Programmer's Reference Manual
,p
2
Horizontal (left) margin measured in dots (default 000).
Vertical (top) margin measured in dots (default 000).
Label path orientated in the center
Printhead Dot Line (832 dots)
p
2
p
1
Reference Point
Direction ZB
Chapter 7—Commands
Maximum Print Width
Reference Point
Direction ZT
Feed Direction
:Creates a 50 dot left margin
and a 100 dot top margin.
p
1
p
2
99